4.2.1.4 Exemplary connections of digital sensors
4.2.1.4.1 Single-channel sensor, without cross-shorting test
DI1
DI2
DI3
DI4
DI13
DI14
P1
P2
L+
L-
X14
X12
.
.
.
Fig.: Single-channel sensor, without cross-shorting test
The single-channel sensor is connected to the PSCBR without clocking or without cross-
shorting test. This design is not recommended for safety applications. Pl b acc. to EN ISO
13849-1 can maximally be reached.
4.2.1.4.2 Single-channel sensor with cross-shorting test
L+
L-
P2
P1
DI1
DI2
DI3
DI4
DI13
DI14
P1
P2
X14
X12
.
.
.
Fig.: Single-channel sensor with cross-shorting test