background image

6

Operating instructions

Safety fieldbox

SFB-PN-IRT-8M12-IOP-V2

EN

4.6  Overview of connections and LED indicators

I

E

I

E

3

2

1

0

7

6

5

4

I

E

I

E

I

E

I

E

I

E

I

E

BF

SF

Err
Pwr

A

L

A

L

P2

P1

Power

I

O

0 1

2

3

4

5

6

7

8

9

0 1

2

3

4

5

6

7

8

9

0 1

2

3

4

5

6

7

8

9

Error LED X3

Device port X3

Input LED X3

Error LED X7
Device port X7
Input LED X7

Error LED X2

Device port X2

Input LED X2

Error LED X6
Device port X6
Input LED X6

Device port X0 – X3

Device port X4 – X7

with FB interface  

for BDF200-FB

Error LED X1

Device port X1

Input LED X1

Error LED X0

Device port X0

Input LED X0

Error LED X5
Device port X5
Input LED X5

Error LED X4
Device port X4
Input LED X4

Link P1 LED

Ethernet port P1

Activity port P1 LED

Link P2 LED
Ethernet port P2
Activity port P2 LED

Fieldbox error LED

Fieldbox power LED

System fault LED
Bus fault LED

Power-IN port

Power-OUT port

FE connection, fieldbox

Rotary coding switch

 

Safety address

Summary of Contents for SFB-PN-IRT-8M12-IOP-V2

Page 1: ...se operating instructions are developed to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the corre...

Page 2: ...rds and the required safety level The non safe IO signals of the connected devices are connected to the control system via the field bus Safety switchgear with parallel IO signals can be connected to...

Page 3: ...LED device port 8 x LED yellow I Input LED device port 2 x LED green L Link LED Ethernet port 2 x LED green A Activity LED Ethernet port 1 x LED green red SF System fault LED 1 x LED red BF Bus fault...

Page 4: ...m Connecting cable male female connectors 103013428 5 0 m Connecting cable male female connectors 101217790 7 5 m Connecting cable male female connectors 103013429 10 0 m Connecting cable male female...

Page 5: ...xchangeable medium has been activated in the F CPU for the PROFINET interface under General Advanced options Interface options 4 3 Power supply and fuse protection The supply voltage of the safety fie...

Page 6: ...evice port X2 Input LED X2 Error LED X6 Device port X6 Input LED X6 Device port X0 X3 Device port X4 X7 with FB interface for BDF200 FB Error LED X1 Device port X1 Input LED X1 Error LED X0 Device por...

Page 7: ...ion Electrostatically sensitive components Do not touch the printed circuit board directly When you open the inspection window ensure that no moisture or excessive humidity penetrates into the fieldbo...

Page 8: ...ED may exhibit the following display and flashing pattern LED display Description GREEN ON Field box in RUN GREEN Flashes Module fault can be acknowledged RED ON Internal field box fault RED 3 Hz F_WD...

Page 9: ...and unlock functions In the event of delayed activation of the lock and unlock function larger systems are possible Device configuration version Max number of devices Equals number of fieldboxes Lengt...

Page 10: ...Electromechanical interlock unlocking function via 1 wire SFB X0 X7 Safety Switch 1 5 A1 DI 2 4 Y1 X1 6 7 Y2 X2 8 3 DO A2 8 3 1 5 2 4 6 7 Diag SCHMERSAL devices AZM 161 FB AZM 170 FB AZM150 ST Electro...

Page 11: ...cibly interrupted SFB X0 X7 2 4 Y1 X1 1 2 Safety Switch Safety Switch 6 7 Y2 X2 1 2 Different safety switchgear Optoelectronic AOPD 8 pin SFB X0 X7 Receiver 1 5 A1 DI 2 4 Y1 X1 6 7 Y2 X2 8 3 DO A2 8 7...

Page 12: ...ervice GmbH Am Grauen Stein 51105 K ln ID n 0035 EC prototype test certificate 01 205 5878 00 22 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279...