background image

SFB-PN-IRT-8M12-IOP-V2

Operating instructions

Safety fieldbox

EN

1

1.  About this document

1.1  Function

These operating instructions provide all the information required for 

mounting, commissioning, safe operation and also disassembly of the 

safety fieldbox. The operating instructions must be available in a legible 

condition and a complete version in the vicinity of the device.

1.2  Further applicable documents

Enter search term “SFB-PN” in the Schmersal Online Catalogue at: 

products.schmersal.com

.

•  Manual: Safety Field Box SFB-PN-V2

•  Operating instructions: Safety Field Box SFB-PN-V2

•  GSDML File

•  Manual: SFB Configuration Tool

1.3  Target group: authorised qualified personnel

All operations described in this operating instructions and in the manual 

must be carried out by trained specialist personnel, authorised by the 

plant operator only.

Please make sure that you have read and understood these operating 

instructions and the manual and that you know all applicable 

legislations regarding occupational safety and accident prevention prior 

to installation and putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.4  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.5  Appropriate use

Products in Schmersal’s range are not intended to be used by private 

end consumers. 

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety fieldbox must only be used according to the following 

versions or for applications that are approved by the manufacturer. 

Detailed information regarding the range of applications can be found in 

the chapter "Product description".

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Further applicable documents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.3 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.4  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.8  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.3  Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

4.2  Notes for replacing the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4.3  Power supply and fuse protection  . . . . . . . . . . . . . . . . . . . . . . . . . .5

4.4  Internal fuse elements device ports . . . . . . . . . . . . . . . . . . . . . . . . .5

4.5  Earth concept and shielding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4.6  Overview of connections and LED indicators  . . . . . . . . . . . . . . . . .6

4.7 

Connector configuration of device ports X0 – X7

. . . . . . . . . . . . . . .7

4.8 

Connector configuration POWER I/O

  . . . . . . . . . . . . . . . . . . . . . . .7

4.9 

Connector configuration PROFINET P1/P2

. . . . . . . . . . . . . . . . . . .7

4.10 

Setting the F-address and factory reset  . . . . . . . . . . . . . . . . . . . .7

5  Diagnostic functions

5.1 

LED indicators, device ports X0 - X7

. . . . . . . . . . . . . . . . . . . . . . . .7

5.2 

LED indicators, PROFINET ports P1/P2

  . . . . . . . . . . . . . . . . . . . . .8

5.3  Central LED indicators, SFB-PN  . . . . . . . . . . . . . . . . . . . . . . . . . . .8

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Annex system configuration

8.1 

Configuration examples of the power supply

. . . . . . . . . . . . . . . . . .9

8.2  Wiring example of the safety switches. . . . . . . . . . . . . . . . . . . . . .

10

9  EU Declaration of conformity

x.000 / 01.2022 / v

.A.   -   103042285-EN / 

A / 2022-01-14 / 

AE-Nr

. -

EN

Operating instructions. . . . . . . . . . . .pages 1 to 12

Original

Summary of Contents for SFB-PN-IRT-8M12-IOP-V2

Page 1: ...se operating instructions are developed to execute safety related functions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the corre...

Page 2: ...rds and the required safety level The non safe IO signals of the connected devices are connected to the control system via the field bus Safety switchgear with parallel IO signals can be connected to...

Page 3: ...LED device port 8 x LED yellow I Input LED device port 2 x LED green L Link LED Ethernet port 2 x LED green A Activity LED Ethernet port 1 x LED green red SF System fault LED 1 x LED red BF Bus fault...

Page 4: ...m Connecting cable male female connectors 103013428 5 0 m Connecting cable male female connectors 101217790 7 5 m Connecting cable male female connectors 103013429 10 0 m Connecting cable male female...

Page 5: ...xchangeable medium has been activated in the F CPU for the PROFINET interface under General Advanced options Interface options 4 3 Power supply and fuse protection The supply voltage of the safety fie...

Page 6: ...evice port X2 Input LED X2 Error LED X6 Device port X6 Input LED X6 Device port X0 X3 Device port X4 X7 with FB interface for BDF200 FB Error LED X1 Device port X1 Input LED X1 Error LED X0 Device por...

Page 7: ...ion Electrostatically sensitive components Do not touch the printed circuit board directly When you open the inspection window ensure that no moisture or excessive humidity penetrates into the fieldbo...

Page 8: ...ED may exhibit the following display and flashing pattern LED display Description GREEN ON Field box in RUN GREEN Flashes Module fault can be acknowledged RED ON Internal field box fault RED 3 Hz F_WD...

Page 9: ...and unlock functions In the event of delayed activation of the lock and unlock function larger systems are possible Device configuration version Max number of devices Equals number of fieldboxes Lengt...

Page 10: ...Electromechanical interlock unlocking function via 1 wire SFB X0 X7 Safety Switch 1 5 A1 DI 2 4 Y1 X1 6 7 Y2 X2 8 3 DO A2 8 3 1 5 2 4 6 7 Diag SCHMERSAL devices AZM 161 FB AZM 170 FB AZM150 ST Electro...

Page 11: ...cibly interrupted SFB X0 X7 2 4 Y1 X1 1 2 Safety Switch Safety Switch 6 7 Y2 X2 1 2 Different safety switchgear Optoelectronic AOPD 8 pin SFB X0 X7 Receiver 1 5 A1 DI 2 4 Y1 X1 6 7 Y2 X2 8 3 DO A2 8 7...

Page 12: ...ervice GmbH Am Grauen Stein 51105 K ln ID n 0035 EC prototype test certificate 01 205 5878 00 22 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279...

Reviews: