Operating instructions

Safety fieldbox

SFB-PN-IRT-8M12-IOP

EN

5.2  LED indicators, PROFINET ports P1/P2

There are 2 LED indicators at the Ethernet ports.

A green link LED and yellow activity LED.

LED link (L)

The link LED may exhibit the following display and flashing pattern:

LED display

Description

GREEN

ON

Connection to Ethernet active

LED Activity (A)

The activity LED may exhibit the following display and flashing pattern:

LED display

Description

YELLOW Flashes

Ethernet data transmission active

5.3  Central LED indicators, SFB-PN

There are 4 LEDs for central diagnostics of the fieldbox. A green/red 

LED indicator for a system fault, a red LED for bus fault, a green/red 

error LED and a green power LED.

System fault LED (SF)

The system fault LED may exhibit the following display and flashing 

pattern:

LED display

Description

RED

ON

Module error or device port error

GREEN

Flashes

FLASH signal for identifying the fieldbox

Bus fault LED (BF)

The bus fault LED may exhibit the following display and flashing 

pattern:

LED display

Description

RED

ON

No or slow connection

RED

Flashes

Connection but no data transmission

Fieldbox error LED (Err)

The error LED may exhibit the following display and flashing pattern:

LED display

Description

GREEN

ON

Field box in RUN

GREEN

Flashes

Module fault can be acknowledged

RED

ON

Internal field box fault

RED

3 Hz

F_WD_Time SFB-PN exceeded

RED

1 impulse

Internal over temperature fault

RED

2 impulses Invalid F address fault

RED

3 impulses

Invalid F_iPar_CRC fault

RED

4 impulses Acknowledge impulse length fault

RED

5 impulses Test pulse output overload fault

RED

6 impulses

Overvoltage fieldbox U > 29 V

Fieldbox power LED (Pwr)

The power LED may exhibit the following display and flashing pattern:

LED display

Description

GREEN

ON

Supply voltage of fieldbox OKAY

GREEN

1 Hz

Low voltage warning U < 20 V

GREEN

3 Hz

Low voltage fault U < 17 V

GREEN

OFF

Fieldbox switched off U < 12 V

6.  Set-up and maintenance

6.1  Functional testing

A check must be carried out to ensure that the projected safety function 

is effective.

The safety functions, configuration of the safety fieldbox and 

correct installation must be checked by a responsible safety 

specialist/safety representative.

6.2  Maintenance

The safety fieldbox operates error-free if installed and used properly.

7.  Disassembly and disposal

7.1  Disassembly

Only disassemble the safety fieldbox if it is in de-energized state.

7.2  Disposal

Dispose of the safety fieldbox properly in accordance with national 

regulations and laws.

Summary of Contents for SFB-PN-IRT-8M12-IOP

Page 1: ...rsions or for applications that are approved by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instruction...

Page 2: ...mation on the commissioning of the safety SFB PN fieldbox can be found on the internet at www schmersal net GSDML file for safety fieldbox SFB PN The dual language GSDML file for the SFB PN can be fou...

Page 3: ...DO digital output should not exceed 850 mA Protection class IP67 is only reached if all M12 connectors and blanking plugs as well as the viewing window are properly fastening with screws 2 4 Safety c...

Page 4: ...nnector 103013430 10 0 m Pre wired cable female connector 103013431 3 0 m Connecting cable male female connectors 103013432 5 0 m Connecting cable male female connectors 103013433 7 5 m Connecting cab...

Page 5: ...3 Internal fuse elements device ports The device ports X0 X7 are designed for 0 8 A continuous current and equipped in each case with an auto resettable fuse of 1 5 A for line protection If the fuse e...

Page 6: ...ice port X2 Input LED X2 Error LED X6 Device port X6 Input LED X6 Device port X0 X3 Device port X4 X7 with FB interface for BDF200 FB Error LED X1 Device port X1 Input LED X1 Error LED X0 Device port...

Page 7: ...rostatically sensitive components Do not touch the printed circuit board directly When you open the inspection window ensure that no moisture or excessive humidity penetrates into the fieldbox The 3 r...

Page 8: ...may exhibit the following display and flashing pattern LED display Description GREEN ON Field box in RUN GREEN Flashes Module fault can be acknowledged RED ON Internal field box fault RED 3 Hz F_WD_T...

Page 9: ...igns are based on simultaneous activation of all lock and unlock functions In the event of delayed activation of the lock and unlock function larger systems are possible Device configuration version M...

Page 10: ...00 Electromechanical interlock interlock function via 1 wire SFB X0 X7 Safety Switch 1 5 A1 DI 2 4 Y1 X1 6 7 Y2 X2 8 3 DO A2 8 3 1 5 2 4 6 7 Diag SCHMERSAL devices AZM 161 FB AZM 170 FB Electronic sen...

Page 11: ...cibly interrupted SFB X0 X7 2 4 Y1 X1 1 2 Safety Switch Safety Switch 6 7 Y2 X2 1 2 Different safety switchgear Optoelectronic AOPD 8 pole SFB X0 X7 Receiver 1 5 A1 DI 2 4 Y1 X1 6 7 Y2 X2 8 3 DO A2 8...

Page 12: ...land Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5719 00 19 Person authorised for the compilation of the technical documentation Oliver Wacker M ddi...

Reviews: