2 Product description
17
2.2 Configurable functions SFB
2.2.1
Parameters of the safety inputs
For each device port there are 2 parameters for configuring the safety inputs.
Parameters
Value range
Default settings
Safety inputs
1 channel / 2 channels
2 channels
Cross fault monitoring
ON / OFF
OFF
Safety inputs
−
1 channel for safety switches with one dry contact, evaluation 1oo1
−
2 channels for safety switches with two dry contacts,
−
2 channels for safety switchgear with 2 OSSDs and test pulses,
evaluation 1oo2
Cross fault monitoring
−
ON for safety switches with one or two dry contacts
−
OFF for safety switchgear with electronic OSSDs
WARNING
The default setting is used for safety switchgear with electronic OSSDs.
If safety switchgear with dry contacts are used, cross fault monitoring
must be activated!
WARNING
For safety switchgear with electronic OSSDs, cross fault detection of the device
connection cable must be carried out by the safety switchgear!
The SFB-PN monitors the test pulses on the outputs of the safety switchgear.
2.2.2
Parameters of the safety outputs
For each device port there are 1 parameter for configuring the safety outputs.
Parameters
Value range
Default settings
Safety outputs
1 wire (PL d) / 2 wires (PL e)
1 wire (PL d)
Safety outputs
−
1 wire (PL d) for safety switchgear with one safety input,
e.g. for solenoid control of interlocks.
−
2 wires (PL e) for safety switchgear with two safety inputs,
e.g. for controlling the locking function of interlocks.