20
2 Product description
2.3 Wiring examples and parameterization
2.3.1
Electronic safety sensor, 8-pole M12 connector
Safety sensor with electronic OSSD, monitoring 1oo2
Parameters
Value
Connection example
Safety inputs
2 channels
Cross-fault detection
OFF
Safety outputs
1 wire (PL d)
Monitoring time
2 s
Stable time
0.1 s
Safety classification
Inputs X1 & X2
−
up to Cat 4 / PL e / SIL 3
Output DO:
−
SCHMERSAL devices: CSS range, RSS range, …
2.3.2
Electronic safety sensor / AOPD, 4/5-pole M12 connector
Safety sensor with electronic OSSD, monitoring 1oo2
Parameters
Value
Connection example
Safety inputs
2 channels
Cross-fault detection
OFF
Safety outputs
1 wire (PL d)
Monitoring time
2 s
Stable time
0.1 s
Safety classification
Inputs X1 & X2
−
up to Cat 4 / PL e / SIL 3
Output DO:
−
Various safety switchgears from different manufacturers.