2 Product description
25
2.3.11 Optoelectronic AOPD SCHMERSAL, 4/8-pole M12 connector
Active opto-electronic protective devices AOPD with electronic OSSD, monitoring 1oo2
Parameters
Value
Connection example
Safety inputs
2 channels
Cross-fault detection
OFF
Safety outputs
1 wire (PL d)
Monitoring time
2 s
Stable time
0.1 s
Safety classification
Inputs X1 & X2
−
up to Cat 4 / PL e / SIL 3
Output DO:
−
SCHMERSAL devices: SLC 440 range, SLG 440 range, …
2.3.12 Optoelectronic AOPD, 4/5-pole M12 connector
Active opto-electronic protective devices AOPD with electronic OSSD, monitoring 1oo2
Parameters
Value
Connection example
Safety inputs
2 channels
Cross-fault detection
OFF
Safety outputs
1 wire (PL d)
Monitoring time
2 s
Stable time
0.1 s
Safety classification
Inputs X1 & X2
−
up to Cat 4 / PL e / SIL 3
Output DO:
−
SCHMERSAL devices: SLC 440-COM range, SLG 440-COM range, SLB 440 range, …