82
7 Annex
Device /
configuration
version
Max.
number of
devices
Number
of field
boxes
Length of cable (A)
until 1st field box
Length of cables (B)
between the field boxes
Length of cables (C)
for device connection
AZM 201 / Maximum
16
2
10.0 m
10.0 m
7.5 m
AZM 201 / Medium
20
2.5
7.5 m
7.5 m
5.0 m
AZM 201 / Small
24
3
7.5 m
5 m
3.5 m
MZM 100 / Maximum
20
2.5
1.0 m
10.0 m
7.5 m
MZM 100 / Medium
24
3
7.5 m
7.5 m
5.0 m
MZM 100 / Small
28
3.5
7.5 m
5 m
3.5 m
AZM 300 / Maximum
28
3.5
10.0 m
10.0 m
7.5 m
AZM 300 / Medium
32
4
7.5 m
7.5 m
5.0 m
AZM 300 / Small
40
5
7.5 m
5 m
3.5 m
AZM 400 / Maximum
16
2
10.0 m
10.0 m
7.5 m
AZM 400 / Medium
16
2
7.5 m
7.5 m
5.0 m
AZM 400 / Small
16
2
7.5 m
5 m
3.5 m
AZM 1xx / Maximum
20
2.5
10.0 m
10.0 m
7.5 m
AZM 1xx / Medium
24
3
7.5 m
7.5 m
5.0 m
AZM 1xx / Small
28
3.5
7.5 m
5 m
3.5 m
RSS, CSS / Maximum
48
6
10.0 m
10.0 m
7.5 m
RSS & CSS / Medium
56
7
7.5 m
7.5 m
5.0 m
RSS & CSS / Small
64
8
7.5 m
5 m
3.5 m
Mixed / Maximum
24
3
10.0 m
10.0 m
7.5 m
Mixed / Medium
28
3.5
7.5 m
7.5 m
5.0 m
Mixed / Small
32
4
7.5 m
5 m
3.5 m
Mixed assembly of the field box: 2 x AZM 201, 2 x MZM 100, 2 x AZM 300
and 2 x RSS / CSS