2.1 Ordering code
SLB 200-
➀
31-21
No.
Option
Description
➀
E
Transmitter
R
Receiver
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Destination and use
In combination with the SLB200-C04-1R safety-monitoring module, the
SLB 200-E/R31-21 one-way safety light barriers are a non-contact safe-
ty guard (ESD, electro-sensitive device) for the protection of hazardous
areas on power-driven work equipment.
LED status indication
Red LED on
Light beam interrupted
Green LED on
Light beam clear
Green-red flashing mode
Soiling, misalignment, distance between
transmitter and receiver too large
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.
2.4 Technical data
Standards:
IEC 61496-1
Enclosure:
ABS
10 % GF
Enclosure dimensions:
31 x 50.5 x 19 mm
Termination:
- Transmitter:
10 cm cable with M8 connector, 3-pole
- Receiver:
10 cm cable with M8 connector, 4-pole
Max. cable length:
50 m
Protection class:
IP67
Response time:
30 ms, in combination with SLB 200-C04-1R
safety monitoring module
Range:
4 m
Start/restart interlock:
yes, in combination with SLB 200-C04-1R
safety monitoring module
Contactor control:
yes, in combination with SLB 200-C04-1R
safety monitoring module
Light emission wavelength:
880 nm
Rated operating voltage U
e
:
24 VDC ± 20%
Safety outputs:
yes, in combination with SLB 200-C04-1R
safety monitoring module
Angle of radiation:
± 4°
Min. size of object:
9 mm Ø
LED status indication:
soiling, switching condition and power on
Ambient temperature:
–10 °C … + 55 °C
Storage and transport temperature:
– 20 °C … + 80 ºC
2.5 Safety classification
(in combination with SLB 200-C04-1R safety monitoring module)
Standards:
ISO 13849-1, IEC 61508, IEC 62061
PL:
d
Control Category:
2
PFH value:
4 x 10
-9
/h
SIL:
suitable for SIL 2 applications
Service life:
20 years
3. Mounting
3.1 General mounting instructions
• The light barriers can be operated in any mounting position (with or
without BF 31 mounting angle). The mounting possibilities are shown
on the dimensional drawing.
• The transmitter and the receiver must be fitted parallel to each other
and at the same mounting height.
• Turn the transmitter whilst observing the display of the receiver and fix
the point at which the LED indication changes from red to green.
• Calculate the max. left and right angle of rotation. Fix the fixing screws
in central position.
• Make sure that the LED indication does not flash red-green or change
to red continuous signal during this process.
Please also observe the notes for the calculation of the
safety distance in the operating instructions manual of
the SLB 200-C04-1R safety-monitoring module.