background image

2

Operating instructions

Safety light barriers

SLB240

EN

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant

The safety device must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer Detailed information regarding the range of applications 

can be found in the chapter "Product description"

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

productsschmersalcom

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications

The entire concept of the control system, in which the 

safety component is integrated, must be validated to  

EN ISO 13849-2

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed

Additional measures could be required to ensure that the system 

does not present a dangerous breakdown, when other forms of light 

beams are available in a special application (eg use of wireless 

control devices on cranes, radiation of welding sparks or effects of 

stroboscopic lights)

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety device is used 

The relevant requirements of the standards EN ISO 13855  

& EN ISO 13857 must be observed.

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device

2.  Product description

2.1  Purpose and use

The SLB is a non-contact, self-testing safety device, which is used 

for the protection of hazardous points, hazardous areas and machine 

access If one or more light beams are interrupted, the hazardous 

movement must be stopped

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level

2.2  Ordering code

This operating instructions manual applies to the following types:

SLB240-ER-

-

No. Option

Description

1

Beam coding 1

2

Beam coding 2

3

Beam coding 3

4

Beam coding 4

ST

Termination male connector

LST

Cable with connector

• Range 03 m  150 m

2.3  Special versions

For special versions, which are not listed in the order code, these 

specifications apply accordingly, provided that they correspond to the 

standard version

2.4  Included in delivery

Transmitter, receiver, operating instructions DE/EN

2.5  Technical data

Standards:

 

EN 61496-1; EN 61496-2; EN ISO 13849; EN 62061

Material of the enclosure:

 Aluminium

Detection ability for test bodies: 

10 mm static 

1)

SLB range: 

03 … 150 m

Reaction time: 

 

- Beam coding 1, impulse pattern 1, 5 samplings:

 

10 ms 

- Beam coding 2, impulse pattern 2, 5 samplings:

 

14 ms 

- Beam coding 3, impulse pattern 3, 5 samplings:

 

18 ms 

- Beam coding 4, impulse pattern 4, 5 samplings:

 

22 ms 

- Beam coding 5, impulse pattern 1, 3 samplings:

 

7 ms

Rated operating voltage:

 

24 VDC ± 10%, 1 A 

PELV mains unit in accordance with EN 60204 (power failure bypass 20 ms)

Rated operating current:

 

100 mA + 200 mA each OSSD

Wavelength of the infrared radiation:

 

880 nm

Transmitter, infrared emitted radiation 

- to DIN EN 12198-1:

 

Category 0

- to DIN EN 62471:

 

free group

Safety outputs 

OSSD1, OSSD2: 

2 x short-circuit proof PNP semi-conductor outputs 

Test impulse cycle OSSD: 

600 ms

Test impulse length: 

max 200 µs

Switching voltage HIGH 

2)

:

 

>15 V

Switching voltage LOW 

2)

:

 

<2 V

Switching current each OSSD:

 

200 mA

Leakage current 

3)

:

 

<1 mA

Load capacity:

 

max 200 nF

Load inductance 

4)

:

 

max 2 H

Inputs:  

 

- Restart:

 

100 ms to 1500 ms monitored 

-   Test:

 

20 ms up to 10 s, monitored  

Input Test LOW:

 

Switching off transmitter = 8 ms  

Input Test HIGH:

 

Switch-on output = 92 ms

Function:

 

Protective mode / Automatic,  

Restart Interlock (manual reset), Setting mode

Status indication receiver:

 

End cap with integrated status indication

Connection: 

 

- Transmitter:

 

connector M12, 4-pole 

- Receiver:

 

connector M12, 5-pole

Ambient temperature:

 

−30° C … + 50° C

Storage temperature:

 

−30° C … + 70° C

Protection class:

 

IP67 (IEC 60529)

Resistance to vibration:

 

10 … 55 Hz to IEC 60068-2-6

Resistance to shock:

 

10 g, 16 ms, to IEC 60028-2-29

Weight: 

SLB240-ST: 0,14 kg, SLB240-LST: 0,15 kg 

Year of construction:

 

as of 2016 version 10

Summary of Contents for SLB240

Page 1: ...warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols...

Page 2: ...are strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device 2 Product description 2...

Page 3: ...nal low Green ON state protection zone uninterrupted OSSD signal high 2 8 2 Protection mode with restart interlock In the operating mode restart interlock the safety switching outputs OSSD remain in t...

Page 4: ...y relevant faults are detected within the reaction time and cause the outputs to be put in the OFF state and an error code is indicated 3 Mounting 3 1 General conditions The following guidelines are p...

Page 5: ...m Prevent the possibility of reaching through between two beams Prevent the possibility of climbing through between two beams Safety distance to the hazardous area S Hazardous point Transmitter Receiv...

Page 6: ...procal interference The response time of the system changes with the selected beam coding The safety distance must be adapted accordingly See section on reaction time When the system starts the integr...

Page 7: ...anual reset Adapter cable for parameter setting Item No Designation Description Length 103013625 KA 0977 Pushbutton with command device 1x male connector M12 5 pole 2x female connector M12 5 pole 3 m...

Page 8: ...achine does not exceed the response time calculated during the first putting into operation 5 The cables the connectors the caps and the mounting angles are in perfect condition 5 5 Cleaning If the op...

Page 9: ...interlock is active SLB waiting for enabling signal Red Status of OSSD safety switch outputs is OFF protection field is not clear Red Alternating OFF pulses signalise the fault status see section on...

Page 10: ...ompilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Deutschland Telefon 49 202 6474 0 Telefax 49 202 6474 100...

Reviews: