background image

6

Operating instructions

Safety light barriers

SLB240

EN

3.6  Interference / Beam coding

If there is a risk of a receiver picking up the light signals from other 

transmitters, each system must be operated with its own beam coding

E

R

E

R

R

E

E

R

No interference

Reciprocal interference!
Beam coding is required

Four different beam codings can be set (see section on setting the 

parameters) The beam coding must be set in pairs (transmitter and 

receiver)

R

E

E

R

R

E

E

R

Reciprocal interference from systems is to be avoided by 

choosing suitable mounting positions or by configuring 

 different beam codings

The user is at risk if systems are operated with reciprocal 

interference

The response time of the system changes with the  selected 

beam coding The safety distance must be adapted 

 accordingly See section on reaction time

When the system starts, the integrated signal lamp indicates 

the set beam coding by the corresponding number of light 

impulses

If an AOPD is operated with no other neighbouring systems, 

beam coding 5 with a very short reaction time (7 milliseconds) 

can be selected

3.7  Dimensions

Dimensions of transmitter and receiver SLB240-ER-x-ST

33

7,6

24

17

¤

5,5

1,5

14,5

10

1,5

48

27,8

91

Dimensions of transmitter and receiver SLB240-ER-x-LST

7,6

¤

5,5

17

1,5

14,5

42,5

27,8

93,5

33

72

24

Cable with connector, length = 200 mm

3.8  Mounting material (Not included in delivery!)

Mounting kit MS-1101

The mounting kit consists of 2 steel angles and 4 fixing screws (Type 

Torx plus 10IP)

5,5

17

28

24

7

11

24

38

Summary of Contents for SLB240

Page 1: ...warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols...

Page 2: ...are strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device 2 Product description 2...

Page 3: ...nal low Green ON state protection zone uninterrupted OSSD signal high 2 8 2 Protection mode with restart interlock In the operating mode restart interlock the safety switching outputs OSSD remain in t...

Page 4: ...y relevant faults are detected within the reaction time and cause the outputs to be put in the OFF state and an error code is indicated 3 Mounting 3 1 General conditions The following guidelines are p...

Page 5: ...m Prevent the possibility of reaching through between two beams Prevent the possibility of climbing through between two beams Safety distance to the hazardous area S Hazardous point Transmitter Receiv...

Page 6: ...procal interference The response time of the system changes with the selected beam coding The safety distance must be adapted accordingly See section on reaction time When the system starts the integr...

Page 7: ...anual reset Adapter cable for parameter setting Item No Designation Description Length 103013625 KA 0977 Pushbutton with command device 1x male connector M12 5 pole 2x female connector M12 5 pole 3 m...

Page 8: ...achine does not exceed the response time calculated during the first putting into operation 5 The cables the connectors the caps and the mounting angles are in perfect condition 5 5 Cleaning If the op...

Page 9: ...interlock is active SLB waiting for enabling signal Red Status of OSSD safety switch outputs is OFF protection field is not clear Red Alternating OFF pulses signalise the fault status see section on...

Page 10: ...ompilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Deutschland Telefon 49 202 6474 0 Telefax 49 202 6474 100...