background image

10

EN

SLB240-A-EN

Operating instructions

Safety light barriers

SLB240

9.  EU Declaration of conformity

Name of the component:

SLB240

Type:

See ordering code

Description of the component:

Safety light barriers

Relevant Directives:

Machinery Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/30/EU

2011/65/EU

Applied standards:

EN 61496-1:2013,

EN 61496-2:2013,

EN ISO 13849-1:2008 + AC:2009,

EN 62061:2005 + A1:2013

Notified body for the prototype test:

TÜV NORD CERT GmbH

Langemarckstr 20, 45141 Essen

ID n°: 0044

EC-prototype test certificate:

44 205 16 019906

Person authorized for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30, 42279 Wuppertal

Deutschland

Telefon:  +49 202 6474-0

Telefax:  +49 202 6474-100

E-Mail: info@schmersal.com

Internet: www.schmersal.com

Place and date of issue:

Mühldorf, Oktober 31, 2016

Authorised signature

Klaus Schuster

Managing Director

Authorised signature

Christian Spranger

Managing Director

EU Declaration of conformity

Original

Safety Control GmbH

Am Industriepark 2a

84453 Mühldorf / Inn

Germany

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives 

The currently valid declaration of conformity can be  

downloaded from the internet at productsschmersalcom

Summary of Contents for SLB240

Page 1: ...warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols...

Page 2: ...are strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device 2 Product description 2...

Page 3: ...nal low Green ON state protection zone uninterrupted OSSD signal high 2 8 2 Protection mode with restart interlock In the operating mode restart interlock the safety switching outputs OSSD remain in t...

Page 4: ...y relevant faults are detected within the reaction time and cause the outputs to be put in the OFF state and an error code is indicated 3 Mounting 3 1 General conditions The following guidelines are p...

Page 5: ...m Prevent the possibility of reaching through between two beams Prevent the possibility of climbing through between two beams Safety distance to the hazardous area S Hazardous point Transmitter Receiv...

Page 6: ...procal interference The response time of the system changes with the selected beam coding The safety distance must be adapted accordingly See section on reaction time When the system starts the integr...

Page 7: ...anual reset Adapter cable for parameter setting Item No Designation Description Length 103013625 KA 0977 Pushbutton with command device 1x male connector M12 5 pole 2x female connector M12 5 pole 3 m...

Page 8: ...achine does not exceed the response time calculated during the first putting into operation 5 The cables the connectors the caps and the mounting angles are in perfect condition 5 5 Cleaning If the op...

Page 9: ...interlock is active SLB waiting for enabling signal Red Status of OSSD safety switch outputs is OFF protection field is not clear Red Alternating OFF pulses signalise the fault status see section on...

Page 10: ...ompilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Deutschland Telefon 49 202 6474 0 Telefax 49 202 6474 100...

Reviews: