6.  Diagnostic

Transmitters and receivers are equipped with an integrated signal lamp 

in the transparent end cap The signal lamp indicates the operating 

status or, in the event of a fault, a fault code

If there are no faults during operation, the status indicator  

on the transmitter goes out after 10 minutes

6.1  Indication of configuration when system starts

The transmitters and receivers indicate the set beam coding once after 

5 seconds when the system starts A number of short light impulses are 

output in the process, which correlates with the number of the beam 

coding

On the receiver, the indicator is delayed until there is no 

change in the ON state or OFF state of the OSSDs for  

5 seconds

6.2  Status display

Transmitter

Display

Status

Blue

Transmitter operation, the indicator is switched off  
10 minutes after start-up

Yellow

Alignment mode

Red

Fault status, see section on fault indication

Cyan,  
magenta

Parameterisation mode,  
see section on parameter setting

Receiver

Display

Status

Green

Status of OSSD safety switch outputs is ON,  
protection field is clear

Yellow

Restart interlock is active,  
SLB waiting for enabling signal

Red

Status of OSSD safety switch outputs 
is OFF, protection field is not clear

Red

Alternating OFF pulses signalise the fault status,  
see section on fault indicator

Yellow,  
cyan,  
magenta

Parameterisation or setup mode,  
see section on parameterisation  
and  setup mode

6.3  Error indication

If there is a fault, red stays on and the fault number is indicated by way 

of OFF impulses The number of impulses indicates the number of the 

fault

Error  

number

Cause

1

Wiring fault, test signal >10 sec

2

Voltage fault in power supply

3

Voltage fault in safety output OSSD1 or OSSD2

5

Incorrect configuration data

6

Internal fault during self-test and diagnosis

7.  Disassembly and disposal

7.1  Disassembly

The safety device must be disassembled in a de-energised condition 

only

7.2  Disposal

The safety device must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations

8.  Appendix

8.1  Contact

Consultancy / Sales:

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Tel: +49 202 6474-0

Fax: +49 202 6474-100

You will also find detailed information regarding our product variety on 

our website: productsschmersalcom

Repair handling / shipping:

Safety Control GmbH

Am Industriepark 2a

84453 Mühldorf/Inn

Germany

Tel: +49 8631 18796-0

Fax: +49 8631 18796-1

Summary of Contents for SLB240

Page 1: ...warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols...

Page 2: ...are strictly forbidden the manufacturer shall accept no liability for damages resulting from such invasive work arbitrary repairs conversions and or modifications to the device 2 Product description 2...

Page 3: ...nal low Green ON state protection zone uninterrupted OSSD signal high 2 8 2 Protection mode with restart interlock In the operating mode restart interlock the safety switching outputs OSSD remain in t...

Page 4: ...y relevant faults are detected within the reaction time and cause the outputs to be put in the OFF state and an error code is indicated 3 Mounting 3 1 General conditions The following guidelines are p...

Page 5: ...m Prevent the possibility of reaching through between two beams Prevent the possibility of climbing through between two beams Safety distance to the hazardous area S Hazardous point Transmitter Receiv...

Page 6: ...procal interference The response time of the system changes with the selected beam coding The safety distance must be adapted accordingly See section on reaction time When the system starts the integr...

Page 7: ...anual reset Adapter cable for parameter setting Item No Designation Description Length 103013625 KA 0977 Pushbutton with command device 1x male connector M12 5 pole 2x female connector M12 5 pole 3 m...

Page 8: ...achine does not exceed the response time calculated during the first putting into operation 5 The cables the connectors the caps and the mounting angles are in perfect condition 5 5 Cleaning If the op...

Page 9: ...interlock is active SLB waiting for enabling signal Red Status of OSSD safety switch outputs is OFF protection field is not clear Red Alternating OFF pulses signalise the fault status see section on...

Page 10: ...ompilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Deutschland Telefon 49 202 6474 0 Telefax 49 202 6474 100...

Reviews: