background image

11

SLB440

SLB450

Operating instructions

Safety light barriers

EN

Operate the machine and check whether the hazardous movement 

stops under the hereafter-mentioned circumstances.

1  Hazardous machine parts do not move when the protection field is 

interrupted

2  The hazardous machine movement is immediately stopped, when 

the protection field is interrupted with the test rod immediately before 

the transmitter, immediately before the receiver and in the middle 

between the transmitter and the receiver

3  No hazardous machine movement when the test rod is within the 

protection field

4  The hazardous machine movement comes to standstill, when the 

voltage supply of the AOPD is switched off

5.4  Half-yearly inspection

The following items must be checked every six months or when a 

machine setting is changed

1  Machine stops or does not inhibit any safety function

2  No machine modification or connection change, which affects the 

safety system, has taken place

3  The outputs of the AOPD are correctly connected to the machine

4  The total response time of the machine does not exceed the 

response time calculated during the first putting into operation

5  The cables, the connectors, the caps and the mounting angles are in 

perfect condition

5.5  Cleaning

If the optics cover of the sensors is extremely soiled, the OSSD outputs 

can be disabled Clean with a clean, soft cloth with low pressure

The use of agressive, abrasive or scratching cleaning agents, which 

could attack the surface, is prohibited

6.  Diagnostic

Transmitters and receivers are equipped with an integrated signal lamp 

in the transparent end cap The signal lamp indicates the operating 

status or, in the event of a fault, a fault code

If there are no faults during operation, the status indicator  

on the transmitter goes out after 10 minutes

6.1  Indication of configuration when system starts

The transmitters and receivers indicate the set beam coding once after 

5 seconds when the system starts A number of short light impulses are 

output in the process, which correlates with the number of the beam 

coding

On the receiver, the indicator is delayed until there is no 

change in the ON state or OFF state of the OSSDs for  

5 seconds

Only SLB450 transmitter:

If the transmitter is configured for alternative range, an 

 additional light impulse is output for two seconds after the 

beam coding has been indicated

6.2  Status display

Transmitter

Display

Status

Blue

Transmitter operation, the indicator is switched off  
10 minutes after start-up

Yellow

Alignment mode

Red

Fault status, see section on fault indication

Cyan,  
magenta

Parameterisation mode,  
see section on parameter setting

Receiver

Display

Status

Green

Status of OSSD safety switch outputs is ON,  
protection field is clear

Yellow

Restart interlock is active,  
SLB waiting for enabling signal

Red

Status of OSSD safety switch outputs 
is OFF, protection field is not clear

Red

Alternating OFF pulses signalise the fault status,  
see section on fault indicator

Yellow,  
cyan,  
magenta

Parameterisation or setup mode,  
see section on parameterisation  
and  setup mode

6.3  Error indication

If there is a fault, red stays on and the fault number is indicated by way 

of OFF impulses The number of impulses indicates the number of the 

fault

Error  

number

Cause

1

Wiring fault

2

Voltage fault in power supply

3

Voltage fault in safety output OSSD1 or OSSD2

4

Fault in heater regulation  
(only SLB450 with integrated heater)

5

Incorrect configuration data

6

Internal fault during self-test and diagnosis

On the SLB450 with integrated heater, if the voltage is out of 

range, a warning is issued by way of white light impulses at 

a frequency of 1 Hz The warning goes out as soon as the 

supply voltage is within the required range

7.  Disassembly and disposal

7.1  Disassembly

The safety device must be disassembled in a de-energised condition 

only

7.2  Disposal

The safety device must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations

8.  Appendix

8.1  Contact

Consultancy / Sales:

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

D-42279 Wuppertal

Tel: +49 (0)2 02 - 64 74 - 0

Fax: +49 (0)2 02 - 64 74 - 100

You will also find detailed information regarding our product variety on 

our website: www schmersalcom

Repair handling / shipping:

Safety Control GmbH

Am Industriepark 2a

D-84453 Mühldorf/ Inn

Tel: +49 (0) 86 31 - 1 87 96 - 0

Fax: +49 (0) 86 31 - 1 87 96 - 1

Summary of Contents for SLB440

Page 1: ...d lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropri...

Page 2: ...ents cannot be excluded when safety device is used The relevant requirements of the standards EN ISO 13855 EN ISO 13857 must be observed Only if the information described in this operating instruction...

Page 3: ...ailure OSSD leakage current The downstream control element must recognise this state as LOW A safety PLC must detect this state 4 The load inductivity generates an induced voltage during the switch of...

Page 4: ...e released as soon as the indicator of the receiver changes from red to yellow and the indicator of the transmitter changes from blue to yellow The AOPD is now in setup mode The signal strength is dis...

Page 5: ...light impulses The better the alignment the higher the frequency of the light pulses The alignment is optimal when the light pulses switch over to continuous light If there is no optical synchronisati...

Page 6: ...fety distance between the safety light barrier and the hazardous point must always be respected and observed If a person reaches the hazardous point before the hazardous movement has come to a standst...

Page 7: ...at risk if systems are operated with reciprocal interference The response time of the system changes with the selected beam coding The safety distance must be adapted accordingly See section on reacti...

Page 8: ...5 m For use in the operating mode Restart Interlock manual reset Adapter cable for parameter setting Item No Designation Description Length 103013625 KA 0977 Pushbutton with command device 1x male con...

Page 9: ...e 1 BK Range 2 WH OSSD 2 BK 0 VDC BU 24 VDC BN Release restart GY 24 VDC BN 0 VDC BU OSSD 1 WH Earth connection S 1 K1 K2 5 1 3 2 4 E1 2 4 1 3 Protective mode Automatic active Delivery state Command d...

Page 10: ...d The operating principle of the AOPD and the machine must be known in order to be able to conduct an inspection If the fitter the planning technician and the operator are different persons please mak...

Page 11: ...ver the indicator is delayed until there is no change in the ON state or OFF state of the OSSDs for 5 seconds Only SLB450 transmitter If the transmitter is configured for alternative range an addition...

Page 12: ...n of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Tele...

Reviews: