SLC 220 IP 69 K
SLG 220 IP 69 K
Operating instructions
Safety light curtain / safety light grid
If liquids with aggressive ingredients are used for cleaning,
please check whether the product used is compatible with the
material of the sensor (refer to chapter "Technical data").
The user must evaluate and design the safety chain in ac-
cordance with the relevant standards and the required safety
level.
2.5 Technical data
Standards:
EN 61496-1; CLC/TS 61496-2;
EN ISO 13849; EN 62061
Material of the enclosure:
Aluminium
Protective tube:
PMMA Plastic tubes
End plugs:
PA 6
Membran:
PA 6, Gore Tex Membran M12 x 1.5
Number of beams:
SLC 220:
6 … 66 (Standard),
SLG 220:
2, 3, 4 beams
Protection field heights :
SLC 220:
175 mm … 1675 mm Standard,
SLG 220:
500 mm, 800 mm, 900 mm
Beam distance:
SLG 220: 300 mm, 400 mm, 500 mm
Reaction time:
SLC 220:
9 … 65 ms,
SLG 220:
12 … 19 ms
Detection sensitivity for test bodies:
30 mm, 80mm
Range of the protection field:
SLC 220:
0,3 … 6 m (standard),
4 … 14 m (high range)
SLG 220:
0,3 … 6 m (standard)
5 … 30 m (high range)
Rated operating voltage:
24 VDC ±10% (PELV) supply unit to
EN 60204 (power drop > 20 ms)
Operating current:
400 mA max. + 0.5 A (OSSD load + output signal
quality load)
Wave length of the sensor:
880 nm
"Safety outputs (OSSD1, OSSD2)":
2 x PNP-type semi-conductor,
short-circuit proof
Switching voltage HIGH¹:
15 … 28,8 V
Switching voltage LOW¹:
0 … 2 V
Switching current:
0 … 200 mA
Leakage current²:
1 mA
Load capacity:
2 µF
Load inductance:
2 H
Admissible conduction resistance between OSSD and load:
2.5 Ω
Supply cable:
1 Ω
Contactor control (EDM):
Input voltage HIGH (inactive):
17 … 29 V
Input voltage LOW (active):
0 … 2,5 V
Input current HIGH:
3 … 10 mA
Input current LOW:
0 … 2 mA
Input restart interlock (manual reset)
Input voltage HIGH (active):
17 … 29 V
Input voltage LOW (inactive):
0 … 2.5 V
Input current HIGH:
11 … 120 mA
Input current LOW:
0 … 2 mA
Function:
SLC 220: Protective mode, start and restart interlock, contactor control,
fixed beam blanking,
SLG 220:
start and restart interlock, contactor control
Signal times
Contactor control:
20 … 300 ms
Restart interlock (manual reset):
20 ms … 1.0 s signal trans-
mission in case of trailing edge
Start interlock:
250 … 1500 ms, adjustable
LED indications transmitter:
Transmitting, status, restart
LED indications receiver:
OSSD ON, OSSD OFF, signal recepti-
on, blanking
Connection:
screwed cable gland M16 x 1,5
Cable length 5,0 m
Cable connector M12 x 1; 8-pole
transmitter and receiver integrated
Ambient temperature:
−10° C … +50° C
Storage temperature:
−25° C … +70° C
Interface:
Diagnostics and function setting
Protection class:
IP69K
Resistance to vibrations:
10 … 55 Hz to IEC 60068-2-6
Resistance to shock:
10 g; 16 ms; to IEC 60068-2-29
Year of construction:
as of 2010 version 1.0
¹) To IEC 61131-2
²) In case of failure, the leakage current at the most flows to the OSSD
cable. The downstream control element must recognise this state as
LOW. A safety PLC must detect this state.
2.6 Response time (reaction time)
The response time depends on the hight of the protected field, the
resolution and the number of light beams.
Resolution 30 mm
Protected
height
[mm]
Beams
[Number]
Response time
[ms]
Weight
[kg]
175
6
12
1.0
250
9
12
1.3
325
12
12
1.4
475
18
16
2.0
625
24
19
2.6
775
30
23
3.2
925
36
27
3.8
1075
42
30
4.4
1225
48
34
5.0
1375
54
37
5.6
1525
60
41
6.2
1675
66
45
6.8
Resolution 80 mm
Protected
height
[mm]
Beams
[Number]
Response time
[ms]
Weight
[kg]
325
4
9
1.4
475
6
10
2.0
625
8
12
2.6
775
10
13
3.2
925
12
15
3.8
1075
14
16
4.4
1225
16
18
5.0
1375
18
19
5.6
1525
20
20
6.2
1675
22
21
6.8
SLG 220 multi-beam version
Beam distance
[mm]
Beams
[Number]
Response time
[ms]
Weight
[kg]
500
2
12
2.3
400
3
16
3.6
300
4
19
3.8
2.7 Safety classification
Standards:
EN ISO 13849-1, EN 62061
PL:
up to d
Control category:
up to 2
PFH value:
3.59 x 10
-8
/ h
SIL:
up to 2
Service life:
20 years