13
EN
SLC 220 IP 69 K
SLG 220 IP 69 K
Operating instructions
Safety light curtain / safety light grid
6.3 Extended diagnostic
By means of the optional configuration software and the NSR-0700
BUS converter, an extended diagnostic can be executed. The software
provides the status information of the component and can represent
the individual light lines. This feature enables an optimal adjustment
of the light curtain. The diagnostic mode is signalled by the OSSD ON
and OSSD OFF LED‘s at the receiver. In diagnostic mode, protective
mode is disabled, the ODDS outputs being locked. The change from
diagnostic mode to protective mode is automatically realised after
Power Reset, when the BUS converter is no longer integrated and the
connecting cable of the sensor is reconnected.
7. Disassembly and disposal
7.1 Disassembly
The safety switchgear must be disassembled in a de-energised condi-
tion only.
7.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.
8. Appendix
8.1 Contact
Consultancy / Sales:
K.A. Schmersal GmbH
Industrielle Sicherheitsschaltsysteme
Möddinghofe 30
D-42279 Wuppertal
Tel:+49 (0) 202 64 74 -0
Fax:+49 (0) 202 64 74- 100
You will also find detailed information regarding our product variety on
our website: www. schmersal.com
Repair handling / shipping:
Safety Control GmbH
Am Industriepark 11
D-84453 Mühldorf / Inn
Tel.: +49 (0) 8631-18796-0
Fax: +49 (0) 8631-18796-1