8
EN
SLC 220 IP 69 K
SLG 220 IP 69 K
Operating instructions
Safety light curtain / safety light grid
3.5 Dimensions
All measurements in mm.
SLC 220 IP69K default transmitter and receiver
60
B
31
24
18
38
A
C
D
23
42
Legend
A Protection field height
B Sensor length
C Mounting dimension
D Total length
Type
A
B
C
D
SLC 220-E/R0175-xx-69-RFB
175
241.5
289.5
325.5
SLC 220-E/R0250-xx-69-RFB
250
304
352
388
SLC 220-E/R0325-xx-69-RFB
325
379
427
463
SLC 220-E/R0475-xx-69-RFB
475
529
577
613
SLC 220-E/R0625-xx-69-RFB
625
679
727
763
SLC 220-E/R0775-xx-69-RFB
775
829
877
913
SLC 220-E/R0925-xx-69-RFB
925
979
1027
1063
SLC 220-E/R1075-xx-69-RFB
1075
1129
1177
1213
SLC 220-E/R1225-xx-69-RFB
1225
1279
1327
1363
SLC 220-E/R1375-xx-69-RFB
1375
1429
1477
1513
SLC 220-E/R1525-xx-69-RFB
1525
1579
1627
1663
SLC 220-E/R1675-xx-69-RFB
1675
1729
1777
1813
All versions with resolution 30 and 80 mm as well as variant (-H) range
from 4.0 to 14.0 m have identical dimensions with the same protection
field height.
For the SLC 220-E/R0175-30-69-RFB type, the dimension changes
from 23 mm to 35,5 mm due to the extended profile length. The protec-
tion field is marked with an individual marking.
SLG 220 multi-beam transmitter and receiver
60
B
31
24
18
38
A
C
D
23
42
82
70
L2
L1
Legend
A Beam distance
B Sensor length
C Mounting dimension
D Total length
Type
A
L1 L2
B
C
D
SLG 220-E/R0500-02-69-RF 500 330 318
604
652
688
SLG 220-E/R0800-03-69-RF 400 230 218
904
952
988
SLG 220-E/R0900-04-69-RF 300 230 218 1004 1052 1088
L1 = Mounting distance (mm) between fixing surface and centre slotted
hole (short end cap)
L2 = Mounting distance (mm) between fixing surface and centre slotted
hole (diagnostic window)