32
TECHNICAL DATA
GENERAL DATA
Safety category
type 4 according to IEC/EN 61496-1 / -2
Response time
≤
30 ms
Reset
automatic or manual (start-/restart interlock)
Power supply
24VDC
±
20%
Connections
Emitter M12 – 5 PINs
Receiver M23 – 19 PINs
Muting sensors M12 – 5 PINs
Protection class
IP 65
Max. length of
electrical connections cable
100 m
Housing cross section
50 x 60 mm
Operating temperature
0
÷
55 °C
Max. humidity
95 %
Safety outputs
2 PNP auto-controlled – 500 mA / 24 VDC
with short-circuit, overload, reversal of polarity protection
Max. output current (OSSD)
500 mA
Leakage output current
< 0.3 mA; in case of failure (interruption of the 0 V supply) max. 0.3 mA
System Status output
PNP – 100 mA at 24 VDC
Max. capacitive load
2,2
µ
F
Max. voltage in off-state
< 1 V
Max. resistance of connections
between OSSDs and the loads
< 25
Ω
* Muting lamp features
24 VDC
Power consumption
min. 0.5 W, max. 5 W
* Response time on
Muting signals (sensors)
100 ms
* Max. duration of muting
Type SLG 415 L/T, SLC/SLG 415 I
with 2 sensors
30 sec or 90 min
* Max. duration of muting
Type SLC/SLG 415 I, SLG 415 T
with 4 sensors
30 sec or infinite
* Max. duration of Override
15 min (renewable)
Max. power consumption
3 W (Emitter)
6 W (Receiver)
*Specifications applicable only to models with Muting function
SLC/SLG 415 I
Protected height
310 ÷ 1810 mm for light curtains with a resolution of 40 and 90 mm
310 ÷ 1210 for light curtains with a resolution of 30 mm
Resolution for the protection of
hands and bodies
30 – 40 – 90 mm
Number of beams for the protection of
limbs
2 – 3 – 4
Range
0 ÷ 16 m
Muting concurrence monitoring
two-way with 2 or 4 sensors - concurrence within 4 s
Muting sensors
External with PNP or relay
Summary of Contents for SLC 415
Page 2: ......
Page 34: ...32 Abbildung 33 Befestigungswinkel Abbildung 34 Befestigungsbolzen...
Page 40: ......
Page 71: ...31 Figure 33 Fastening brackets Figure 34 Fastening inserts...
Page 78: ......
Page 116: ......