background image

3

SRB 202MSL

Operating instructions

Safety-monitoring module

EN

Fuse rating of the signalling outputs:

 

LA1 / LA2, F2, F3 = T 0.5 A

Utilisation category to IEC/EN 60947-5-1:

 DC-13: 

 

EN 60947-5-1

Dimensions (H/W/D):  

100 mm x 45 mm x 121 mm

The data specified in this manual are applicable when the component is 

operated with rated operating voltage U

e

 ±0%.

2.5  Safety classification

Standards:

 

EN ISO 13849-1, IEC 61508,  

EN 60947-5-1, DIN EN 61496-1

PL:

 

up to e

Control category:

 

up to 4

DC:

 

Stop 0: 99% (high)

CCF:

 

> 65 points

SIL:

 

up to 3

Service life: 

20 years

B

10D

 value (for one channel):

 

Low voltages range 20%: 20,000,000 

40%: 7,500,000 

60%: 2,500,000 

80%: 1,000,000 

Maximum load 100%: 400,000

MTTF

B

d x

x

h

s/h

3600

D

10D

op

op

op

n

0,1 x n

op

t

cycle

For an average annual demand rate of n

op

 = 126,720 cycles per year, 

Performance Level PL e can be obtained at maximum load.

n

op

  = average number of activations per year

d

op

  = average number of operating days per year

h

op

  = average number of operating hours per day

t

cycle

  =  average demand rate of the safety function in s  

(e.g. 4 × per hour = 1 × per 15 min. = 900 s)

(Specifications can vary depending on the application-specific 

parameters h

op

, d

op

 and t

cycle

 as well as the load.)

3.  Mounting

3.1  General mounting instructions

Mounting: snaps onto standard DIN rails to EN 60715.

Snap the bottom of the enclosure slightly tilted forwards in the DIN rail 

and push up until it latches in position.

3.2  Dimensions

All measurements in mm.

Device dimensions (H/W/D): 100 x 45 x 121 mm

with plugged-in terminals: 120 × 45 × 121 mm

4.  Rear side Electrical connection

4.1  General information for electrical connection

The electrical connection may only be carried out by 

authorised personnel in a de-energised condition.

Wiring examples: see appendix

5.  Operating principle and settings

5.1  LED functions

K1: Status reset

 K2: Status channel 1

 K3: Status channel 2

K4: Status monitoring channel 1

K5: Status monitoring channel 2

LA: Status LA1-LA2

UB: Status operating voltage (LED is on, when the operating voltage  

on the terminals A1-A2 is ON)

U

i

: Status internal operating voltage (LED is on, when the operating 

voltage on the terminals A1-A2 is ON and the fuse has not been 

triggered)

5.2  Description of the terminals

Voltages: A1

A2

24 VDC
0 VDC

Inputs:

S11-S12
S12-S13
S21-S22
X1-MR

Input channel S1-S3 (+)
Input channel S1-S3 (–)
Input channel S2-S4 (+)
Master reset

Outputs:

13-14
23-24
X13-14
X23-24
LA1-LA2

First safety enabling circuit (stop 0)
Second safety enabling circuit (STOP 0)
Bridging first enabling circuit
Bridging second enabling circuit
Muting lamp

Start:

X1-X2

Feedback circuit

Signalling 
outputs:

L54
L84

Signalling output
Signalling output

U

B

U

i

K1

K2

K3

K4

K5

LA

A1 X1 X2 MR

S11 S12 S13

S22

S21

S23

X23 L84 X13

24

LA1 13 23 L54

LA2 14

A2

SRB 202MSL

L84: 0,24 A

Fig. 1

Summary of Contents for SRB 202MSL

Page 1: ...monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation st...

Page 2: ...1508 2 SILCL 3 to DIN EN 62061 meets the requirements of control category 4 to DIN EN 954 1 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an analysis of all relevant components is required 2 4 Technical data General data Standards IEC EN 60204 1 EN 60947 5 1 EN ISO 13849 1 IEC EN 61508 DIN EN 61496 1 Climate resistance EN 60068 ...

Page 3: ... 60715 Snap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D 100 x 45 x 121 mm with plugged in terminals 120 45 121 mm 4 Rear side Electrical connection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel ...

Page 4: ... S12 S13 S22 S21 S23 X23L84X13 24 LA1 13 23 L54 LA2 14 A2 SRB 202MSL L84 0 24 A UB Ui K1 K2 K3 K4 K5 LA A1 X1 X2 MR S11 S12 S13 S22 S21 S23 X23L84X13 24 LA1 13 23 L54 LA2 14 A2 SRB 202MSL L84 0 24 A R1 Fig 2 Fig 3 6 Set up and maintenance 6 1 Functional testing The safety function of the safety monitoring module must be tested The following conditions must be previously checked and met 1 Correct f...

Page 5: ...ts d Elan safety relay X1 S11 S1 S3 S2 S4 X2 a c 24V b S12 LA1 S22 LA2 S23 X13 14 13 24 23 X23 UB Ui K1 K2 K3 K4 K5 LA SRB 202MSL L84 A d K1 K2 K3 Fig 6 a Muting sensors b Bridge c AOPD semi conductor outputs d Elan safety relay X1 S12 S11 X2 a c 24 V b S13 S21 LA1 S22 LA2 S23 X13 14 13 24 23 X23 UB Ui K1 K2 K3 K4 K5 LA SRB 202MSL L84 A d K1 K2 K3 Fig 7 a Semi conductor muting sensors b Bridge c A...

Page 6: ...nitoring module The input MR reacts on a rising edge S12 S11 S1 KA KB S23 S22 S2 X2 X1 J MR X1 Master J Fig 9 Fig 10 8 3 Actuator configuration Dual channel control with feedback circuit Fig 11 Suitable for increase in capacity or number of contacts by means of contactors or relays with positive guided contacts S feedback circuit If the feedback circuit is not required establish a bridge X1 X2 13 ...

Page 7: ...oth in their basic design and construction conform to the applicable European Directives Name of the component SRB202MSL Description of the component Safety monitoring module for emergency stop circuits and guard door monitoring Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2004 AC 2005 A1 2009 EN ISO 13849 1 20...

Page 8: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: