background image

2

Operating instructions

Safety-monitoring module

SRB 207AN-230V

EN

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  

the safety-monitoring module, personal hazards or damage  

to machinery or plant components cannot be excluded.  

The relevant requirements of the standards ISO 14119 and 

ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The safety-monitoring module must only be used when the enclosure is 

closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB 207AN-230V

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and 

therefore the compliance with the Machinery Directive is 

maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

The safety-monitoring module for integration in safety circuits is 

designed for fitting in control cabinets. It is used for the safe evaluation 

of the signals of positive break position switches for safety functions 

or magnetic safety sensors on sliding, hinged and removable safety 

guards as well as emergency stop control devices. Up to 6 safety 

guards can be monitored by means of the SRB 207AN-230V safety-

monitoring module.

Design

The safety-monitoring module has a multichannel structure. It includes 

safety relays with monitored positive action contacts. The NO contacts 

of the relays, which are wired in series, build the enabling contacts. 6 

signalling outputs signal the position of the corresponding safety guard.

The entire concept of the control system in which the safety 

component is integrated, must be validated to the relevant 

standards.

2.4  Technical data

Standards:

 

IEC/EN 60204-1; EN 60947-5-1; EN 60947-5-3; 

EN ISO 13849-1; IEC 61508;  

BG-GS-ET-14; BG-GS-ET-20

Start conditions:

 

Automatic or start button (optionally monitored)

Feedback circuit available:

 yes

Start-up test:

 no

Pull-in delay for automatic start: 

 

typ. 120 ms

Pull-in delay with reset button:

 

typ. 30 ms

Drop-out delay in case of emergency stop:

 

typ. 20 ms 

Rated operating voltage U

e

:

 

48 … 240 VAC

Rated insulation voltage U

i

:

 

250 V

Rated impulse withstand voltage U

imp

:

 

4 kV

Thermal test current I

the

:

 

6 A

Internal electronic fuse (Y/N):

 

ja, tripping current > 1.0 A,  

reset after approx. 1 sec.

Power consumption: 

6.8 VA

Inputs monitoring: 

Cross-wire short detection:

 yes

Wire breakage detection: 

yes

Earth connection detection: 

yes

Number of NC contacts:

 6

Number of NO contacts:

 6

Max. total line resistance:

 

40 Ω

Outputs: 

Stop category 0:

 2

Stop category 1:

 0

Number of safety contacts:

 2

Number of auxiliary contacts:

 1

Number of signalling outputs:  

6

Switching capacity of the auxiliary contacts:

 

A1.1-32: 24 VDC / 2 A

Switching capacity of the signalling outputs:

 

Y1 … Y6:  

24 VDC (external) / 20 mA

Fuse rating of the signalling outputs:

 

external fuse rating, 

Output current: A1.1-32: 2 A 

Y1 … Y6: je 20 mA

Max. switching capacity of the safety contacts: 

 

250 VAC, 6 A ohmic (inductive in case of appropriate protective wiring)

Utilisation category to EN 60947-5-1:

 

AC-15: 250 V / 6 A 

 

DC-13: 24 V / 6 A

Max. fuse rating:

 

6 A gG D-fuse

Mechanical life: 

10 million operations

LED display:

 3

Ambient conditions: 

Operating temperature:

 

−25 °C ... +45 °C

Storage and transport temperature:

 

−25 °C ... +70 °C

Protection class: 

Enclosure: IP40  

Terminals: IP20  

Clearance: IP54

Degree of pollution:

 2

Mounting:  

Snaps onto standard DIN rail to EN 60715

Connection type:

 

plug-in screw connection

Min. cable section:

 

0.25 mm²

Max. cable section:

 

2.5 mm², rigid or flexible

Weight:

  

400 g

Dimensions H × W × D:

 

100 × 45 × 121 mm

The data specified in this manual is applicable when the component is 

operated with rated operating voltage U

e

 ±0%.

2.5  Safety classification

Standards:

 

EN ISO 13849-1; IEC 61508

PL:

 

up to d

Control category:

 

up to 3

PFH-value:

 

1.0 x 10

-7

 / h; applicable for applications  

with up to max. 50,000 switching cycles / year  

and max. 80 % contact load. Diverging applications upon request.

SIL:

 

up to 2

Service life: 

20 years

Reviews: