2
Operating instructions
Safety-monitoring module
SRB 207AN-230V
EN
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of inadequate or improper use or manipulations of
the safety-monitoring module, personal hazards or damage
to machinery or plant components cannot be excluded.
The relevant requirements of the standards ISO 14119 and
ISO 13850 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
The safety-monitoring module must only be used when the enclosure is
closed, i.e. with the front cover fitted.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
SRB 207AN-230V
Only if the information described in this operating instructions
manual are realised correctly, the safety function and
therefore the compliance with the Machinery Directive is
maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Purpose
The safety-monitoring module for integration in safety circuits is
designed for fitting in control cabinets. It is used for the safe evaluation
of the signals of positive break position switches for safety functions
or magnetic safety sensors on sliding, hinged and removable safety
guards as well as emergency stop control devices. Up to 6 safety
guards can be monitored by means of the SRB 207AN-230V safety-
monitoring module.
Design
The safety-monitoring module has a multichannel structure. It includes
safety relays with monitored positive action contacts. The NO contacts
of the relays, which are wired in series, build the enabling contacts. 6
signalling outputs signal the position of the corresponding safety guard.
The entire concept of the control system in which the safety
component is integrated, must be validated to the relevant
standards.
2.4 Technical data
Standards:
IEC/EN 60204-1; EN 60947-5-1; EN 60947-5-3;
EN ISO 13849-1; IEC 61508;
BG-GS-ET-14; BG-GS-ET-20
Start conditions:
Automatic or start button (optionally monitored)
Feedback circuit available:
yes
Start-up test:
no
Pull-in delay for automatic start:
typ. 120 ms
Pull-in delay with reset button:
typ. 30 ms
Drop-out delay in case of emergency stop:
typ. 20 ms
Rated operating voltage U
e
:
48 … 240 VAC
Rated insulation voltage U
i
:
250 V
Rated impulse withstand voltage U
imp
:
4 kV
Thermal test current I
the
:
6 A
Internal electronic fuse (Y/N):
ja, tripping current > 1.0 A,
reset after approx. 1 sec.
Power consumption:
6.8 VA
Inputs monitoring:
Cross-wire short detection:
yes
Wire breakage detection:
yes
Earth connection detection:
yes
Number of NC contacts:
6
Number of NO contacts:
6
Max. total line resistance:
40 Ω
Outputs:
Stop category 0:
2
Stop category 1:
0
Number of safety contacts:
2
Number of auxiliary contacts:
1
Number of signalling outputs:
6
Switching capacity of the auxiliary contacts:
A1.1-32: 24 VDC / 2 A
Switching capacity of the signalling outputs:
Y1 … Y6:
24 VDC (external) / 20 mA
Fuse rating of the signalling outputs:
external fuse rating,
Output current: A1.1-32: 2 A
Y1 … Y6: je 20 mA
Max. switching capacity of the safety contacts:
250 VAC, 6 A ohmic (inductive in case of appropriate protective wiring)
Utilisation category to EN 60947-5-1:
AC-15: 250 V / 6 A
DC-13: 24 V / 6 A
Max. fuse rating:
6 A gG D-fuse
Mechanical life:
10 million operations
LED display:
3
Ambient conditions:
Operating temperature:
−25 °C ... +45 °C
Storage and transport temperature:
−25 °C ... +70 °C
Protection class:
Enclosure: IP40
Terminals: IP20
Clearance: IP54
Degree of pollution:
2
Mounting:
Snaps onto standard DIN rail to EN 60715
Connection type:
plug-in screw connection
Min. cable section:
0.25 mm²
Max. cable section:
2.5 mm², rigid or flexible
Weight:
400 g
Dimensions H × W × D:
100 × 45 × 121 mm
The data specified in this manual is applicable when the component is
operated with rated operating voltage U
e
±0%.
2.5 Safety classification
Standards:
EN ISO 13849-1; IEC 61508
PL:
up to d
Control category:
up to 3
PFH-value:
1.0 x 10
-7
/ h; applicable for applications
with up to max. 50,000 switching cycles / year
and max. 80 % contact load. Diverging applications upon request.
SIL:
up to 2
Service life:
20 years