background image

SRB 211AN V.2 / CC V.2 / PC V.2

Operating instructions
Safety-monitoring module

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety-monitoring module. The opera-
ting instructions must be available in a legible condition and a complete 
version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The safety-monitoring module must be exclusively used in accordance 
with the versions listed below or for the applications authorised by the 
manufacturer. Detailed information regarding the range of applications 
can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is  
provided without liability and is subject to technical modifications.

The entire concept of the control system, in which the  
safety component is integrated, must be validated to  
EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.6  Derating curve  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3

Operating principle and settings

5.1  LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2  Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3  Notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.4  Setting report SRB 211 AN  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 

Start coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.3 

Sensor coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

8.4 

Actuator coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Declaration of conformity

9.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

x.000 / Oktober 2013 / v

.A.   -   101209240-EN / C / 2013-09-30 / 

AE-Nr

. 2871

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Translation of the original operating instructions

Summary of Contents for SRB 211AN V.2

Page 1: ...acturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this o...

Page 2: ...ontrol category 4 PL e to DIN EN ISO 13849 1 Corresponds to SIL 3 to DIN EN 61508 2 SILCL 3 to DIN EN 62061 The safety relevant current paths with the outputs contacts 37 38 meet the following require...

Page 3: ...75 087 7 0 min 80 30 918 17 0 min 100 12 223 43 0 min 2 6 Derating curve 21 A 18 A 15 A 12 A 9 A 6 A 3 A 0 A 35 C 40 C 45 C 50 C 55 C 60 C 65 C Fig 1 vertical residual current horizontal ambient tempe...

Page 4: ...hes can be set when the operating voltage is on however in order for the setting to be saved in the SRB 211ST the voltage supply must be interrupted for approx 3 seconds The set drop out delay must be...

Page 5: ...sposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Wiring examples Dual channel control show...

Page 6: ...hing current min 10 mA For example the following safety sensors meet the requirements BNS 33 11z BNS 33 11z 2063 BNS 33 11zG 2237 BNS 250 11z BNS 250 11zG BNS 120 11z BNS 180 11z BNS 303 11z BNS 303 1...

Page 7: ...Person authorized for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Notiied body which approved the full quality assurance system referred to in Appendix...

Page 8: ...KG Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E mail info schmersal com Internet...

Reviews: