background image

7

SRB 211AN V.2 / CC V.2 / PC V.2

Operating instructions
Safety-monitoring module

EN

SRB21

1AN V2-C-EN

9.  Declaration of conformity

The currently valid declaration of conformity can be  
downloaded from the internet at www.schmersal.net.

9.1  EC Declaration of conformity

Name of the safety component:

SRB 211AN V.2;  
SRB 211AN/CC V.2;  
SRB 211AN/PC V.2

Description of the safety component:

Safety-monitoring module for emergency 
stop circuits, guard door monitoring and 
magnetic safety switches

Relevant EC-Directives:

2006/42/EC-EC-Machinery Directive
2004/108/EC EMC-Directive

Person authorized for the compilation 
of the technical documentation:

Oliver Wacker
Möddinghofe 30
42279 Wuppertal

Notiied body, which approved the full 

quality assurance system, referred to  
in Appendix X, 2006/42/EC:

TÜV Rheinland Industrie Service GmbH
Alboinstraße 56
12103 Berlin
ID n°: 0035

Place and date of issue:

Wuppertal, September 30, 2013

Authorised signature

Philip Schmersal

Managing Director

EC Declaration of conformity

Translation 
of the original Declaration of Conformity

K.A. Schmersal GmbH & Co. KG 

Industrielle Sicherheitsschaltsysteme
Möddinghofe 30, 42279 Wuppertal
Germany
Internet: www.schmersal.com

We hereby certify that the hereafter described safety components both in its basic design and  
construction conform to the applicable European Directives.

Summary of Contents for SRB 211AN V.2

Page 1: ...acturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this o...

Page 2: ...ontrol category 4 PL e to DIN EN ISO 13849 1 Corresponds to SIL 3 to DIN EN 61508 2 SILCL 3 to DIN EN 62061 The safety relevant current paths with the outputs contacts 37 38 meet the following require...

Page 3: ...75 087 7 0 min 80 30 918 17 0 min 100 12 223 43 0 min 2 6 Derating curve 21 A 18 A 15 A 12 A 9 A 6 A 3 A 0 A 35 C 40 C 45 C 50 C 55 C 60 C 65 C Fig 1 vertical residual current horizontal ambient tempe...

Page 4: ...hes can be set when the operating voltage is on however in order for the setting to be saved in the SRB 211ST the voltage supply must be interrupted for approx 3 seconds The set drop out delay must be...

Page 5: ...sposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Wiring examples Dual channel control show...

Page 6: ...hing current min 10 mA For example the following safety sensors meet the requirements BNS 33 11z BNS 33 11z 2063 BNS 33 11zG 2237 BNS 250 11z BNS 250 11zG BNS 120 11z BNS 180 11z BNS 303 11z BNS 303 1...

Page 7: ...Person authorized for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Notiied body which approved the full quality assurance system referred to in Appendix...

Page 8: ...KG Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E mail info schmersal com Internet...

Reviews: