2

Operating instructions
Safety-monitoring module

SRB 302X3

EN

The entire concept of the control system, in which the  
safety component is integrated, must be validated to  
EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  
the safety-monitoring module, personal hazards or damage  
to machinery or plant components cannot be excluded. 
The relevant requirements of the standards EN 1088 and  
EN ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages resulting 
from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

The safety-monitoring module must only be used when the enclosure is 
closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB 302X3 

No.

Option

Description

24V/230V

24VAC/DC / 230 VAC

24V/115V

24VAC/DC / 115VAC

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 
designed for fitting in control cabinets. They are used for the safe 
evaluation of the signals of positive break position switches for safety 
functions on sliding, hinged and removable safety guards as well as 
emergency stop control devices and AOPD's (light barriers).

The safety function is defined as the opening of enabling circuits 13-14, 
23-24 and 33-34 when the inputs S11-S12 and/or S21-S22 and/or 
S31-S32 are opened. The safety-relevant current paths with the output 
contacts 13-14, 23-24 and 33-34 meet the following requirements under 
observation of a B

10d 

value assessment (also refer to "Requirements to 

DIN EN ISO 13849-1"): 
– control category 4 – PL e to DIN EN ISO 13849-1 
– corresponds to SIL 3 to DIN EN 61508-2 
–  corresponds to SILCL 3 to DIN EN 62061 

(corresponds to control category 4 to DIN EN 954-1)

To determine the Performance Level (PL) of the entire safety function 
(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 
relevant components is required.

2.4  Technical data
General data: 

Standards:

 

IEC/EN 60204-1, EN 60947-5-1,  

EN ISO 13849-1, IEC/EN 61508

Climate resistance:

  

EN 60068-2-78

Mounting:  

Snaps onto standard DIN rail to EN 60715

Terminal designations:

  

EN 60947-1

Material of the housings:

 

Plastic, glass-fibre reinforced  

thermoplastic, ventilated

Material of the contacts: 

AgSnO, self-cleaning, positive drive

Weight:

  

450 g

Start conditions:

 

Automatic or start button (monitored)

Feedback circuit available:

 yes

Pull-in delay:

 

typ. 20 ms 

Drop-out delay in case of emergency stop:

 

typ. 20 ms

Drop-out delay on "supply failure":

 

typ. 60 ms

Mechanical data: 

Connection type:

 

Screw connection

Cable section:

 

Min. 0,25 mm² / max. 2,5 mm²

Connecting cable:

  

rigid or flexible

Tightening torque for the terminals:

  

0.6 Nm

With removable terminals:

 No

Mechanical life: 

10 million operations

Resistance to shock:

 

10 g / 11 ms

Resistance to vibrations to EN 60068-2-6:

 

10 … 55 Hz,  

amplitude 0.35 mm

Ambient temperature:

 

– 25 °C … +60 °C

Storage and transport temperature:

 

– 40 °C … +85 °C

Protection class: 

Enclosure: IP40  

Terminals: IP20  

Clearance: IP54

Air clearances and creepage  

 

distances to IEC/EN 60664-1:

 

4 kV/2 (basic insulation)

EMC rating:  

to EMC Directive

Electrical data: 

Contact resistance in new state:

 

max. 100 mΩ

Power consumption: 

max. 2.5 W / 5.0 VA

Rated operating voltage U

e

:

 

24 VDC: –15% / +20%,  

residual ripple max. 10% 

24 VAC: –15% / +10% (Terminals B1-B2) 

115/230 VAC: –15% / +10% (Terminals A1-A2)

Frequency range: 

50 / 60 Hz

Fuse rating for the operating voltage: 

Internal electronic trip,  

tripping current: > 1.0 A

Current and voltage at the control circuits: 

 

- S11, S12:

 

24 VDC, continuous current: 80 mA; 

- S21, S22:

 

24 VDC, continuous current: 40 mA,  

start impulse: 450 mA / 5 ms; 

- S31, S32:

 

24 VDC, continuous current: 40 mA; 

- S13, S14:

 

24 VDC, start impulse: 150 mA / 20 ms; 

- S33, S34:

 

24 VDC, start impulse: 200 mA / 5 ms

Monitored inputs: 

Cross-wire detection:

 optional

Wire breakage detection: 

yes

Earth connection detection: 

yes

Number of NO contacts:

 0

Number of NC contacts:

 2

Conduction resistance:

 

max. 10 Ω

Outputs: 

Number of safety contacts:

 3

Number of auxiliary contacts: 

2

Number of signalling outputs:  

0