2

Operating instructions
Safety-monitoring module

SRB 308IT

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages resulting 
from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modiications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modiications 

to the device.

2  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB 308IT-

No.

Option

Description

24 V

24VDC/24VAC

115 V

115VAC

230 V

230VAC

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these speciications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are  

designed for itting in control cabinets. They are used for the safe 

evaluation of the signals of positive break position switches or magnetic 
safety sensors for safety functions on sliding, hinged and removable 
safety guards as well as emergency stop control devices and AOPD's.

The safety function is deined as the opening of enabling circuits 13-14, 

 

23-24 and 33-34 when the inputs S11-S12 and/or S21-S22 and/or  
S31-S32 are opened. The safety-relevant current paths with output 
contacts 13-14, 23-24 and 33-34 meet the following requirements  
under observation of a B

10d

 value assessment (also refer to 

“Requirements of DIN EN ISO 13 849-1“):

– Category 4 - PL e to DIN EN ISO 13849-1 
– SIL 3 to DIN EN 61508-2 
–  SILCL 3 to DIN EN 62061  

(meets the requirements of control category 4 to DIN EN 954-1)

To determine the Performance Level (PL) of the entire safety function 

(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 

relevant components is required.

2.4  Technical data

General data

Standards:

IEC/EN 60204-1, EN 60947-5-1; 

 

EN ISO 13849-1, IEC/EN 61508

Climate resistance:

EN 60068-2-78

Fixing:

Snaps onto standard DIN rails  
to DIN EN 60715

Terminal designations:

EN 60947-1

Material of the enclosure:

glass-ibre reinforced thermoplastic, 

ventilated

Material of the contacts:

AgSnO, self-cleaning, positive drive

Weight:

24VDC/24VAC: 340 g
115VAC / 230VAC: 400 g

Start conditions

automatic or start button  

(optionally monitored)

Feedback circuit (Y/N):

Yes

Pull-in delay with  
automatic start:

typ. 60 ms

Pull-in delay with reset button:

typ. 200 ms

Drop-out delay in case  
of emergency stop:

typ. 15 ms

Drop-out delay on  
"supply failure":

on request

Mechanical data

Connection type:

Screw terminals

Cable section:

min. 0.25 mm

2

 / max. 2.5 mm

2

Connecting cable:

rigid or lexible

Tightening torque for  
the terminals:

0.6 Nm

With removable terminals (Y/N):

Yes

Mechanical life:

10 million operations

Electrical life:

Derating curve available on request

Resistance to shock:

10 g / 11 ms

Resistance to vibrations  
to EN 60068-2-6:

10 ... 55 Hz, amplitude 0.35 mm

Ambient conditions

Ambient temperature:

–25°C … +45°C

Storage and transport  
temperature:

–40°C … +85°C

Protection class:

Enclosure: IP 40
Terminals: IP 20
Wiring compartment: IP 54

Air clearances and creepage 
distances to IEC/EN 60664-1:

4 kV/2 (basic insulation)

EMC rating:

to EMC Directive

Electrical data

Contact resistance in new state:

max. 100 mΩ

Power consumption:

max. 3 W / 3 VA

Rated operating voltage U

e

:

24 VDC:

15% / +20%,  
residual ripple max. 10%

230 VAC / 115 VAC / 24 VAC:

15% / +10%

Frequency range:

50 Hz / 60 Hz

Max. fuse rating of the  
operating voltage:

Internal electronic trip,  
tripping current F1: > 0.5 A,  
Reset after disconnection  
of supply voltage

Monitored inputs

Cross-wire detection (Y/N):

Yes

Wire breakage detection (Y/N):

Yes

Earth leakage detection (Y/N):

Yes

Number of NO contacts:

0

Number of NC contacts:

2

Cable lengths:

– 1,500 m = 1.5 mm² 
– 2,500 m = 2.5 mm² 
1-channel 
2-channel without cross-wire  
short detection

Conduction resistance:

max. 40 Ω

Summary of Contents for SRB 308IT

Page 1: ...unctions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant The safety monitor...

Page 2: ...3 to DIN EN 62061 meets the requirements of control category 4 to DIN EN 954 1 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an an...

Page 3: ...cations can vary depending on the application speciic parameters hop dop and tcycle as well as the load 3 Mounting 3 1 General mounting instructions Mounting snaps onto standard DIN rails to EN 60715...

Page 4: ...e safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 5 3 Notes Indications Status A Module off B Module off C Module s...

Page 5: ...ging the terminals X3 X6 Caution Not admitted without additional measure due to the risk of gaining access by stepping behind within the meaning of EN 60204 1 2006 paragraph 9 2 5 4 2 and 10 8 3 the o...

Page 6: ...ding to EN 60947 5 3 see Fig 17 The control system recognises wire breakage and earth faults in the control circuit Cross wire shorts between the control circuits are not detected Possible control cat...

Page 7: ...ts If the feedback circuit is not required establish a bridge S Feedback circuit if the feedback circuit is not required establish a bridge Dual channel control with feedback circuit Fig 20 Suitable f...

Page 8: ...fety monitoring module for emergency stop circuits guard door monitoring magnetic safety switches and AOPD s Harmonised EC Directives 2006 42 EC EC Machinery Directive 2004 108 EC EMC Directive Person...