Operating instructions
Safety-monitoring module

EN

8.4 

Actuator coniguration

Single-channel control with feedback circuit (Fig. 19)

• 

Suitable for increase in capacity or number of contacts by means  
of contactors or relays with positive-guided contacts.

• 

If the feedback circuit  
is not required, establish a bridge.

• 

 

S

 = Feedback circuit: 

if the feedback circuit is not required, establish a bridge.

Dual-channel control with feedback circuit (Fig. 20)

• 

Suitable for increase in capacity or number of contacts by means  
of contactors or relays with positive-guided contacts.

• 

 

S

 = Feedback circuit: 

if the feedback circuit is not required, establish a bridge.

X1

X2

13

14

K

A

S

L1

N

K

A

X1

X2

13

14

K

A

S

L1

N

K

B

K

A

K

B

Fig. 19

Fig. 20

Summary of Contents for SRB 308IT

Page 1: ...unctions as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant The safety monitor...

Page 2: ...3 to DIN EN 62061 meets the requirements of control category 4 to DIN EN 954 1 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an an...

Page 3: ...cations can vary depending on the application speciic parameters hop dop and tcycle as well as the load 3 Mounting 3 1 General mounting instructions Mounting snaps onto standard DIN rails to EN 60715...

Page 4: ...e safety monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations 5 3 Notes Indications Status A Module off B Module off C Module s...

Page 5: ...ging the terminals X3 X6 Caution Not admitted without additional measure due to the risk of gaining access by stepping behind within the meaning of EN 60204 1 2006 paragraph 9 2 5 4 2 and 10 8 3 the o...

Page 6: ...ding to EN 60947 5 3 see Fig 17 The control system recognises wire breakage and earth faults in the control circuit Cross wire shorts between the control circuits are not detected Possible control cat...

Page 7: ...ts If the feedback circuit is not required establish a bridge S Feedback circuit if the feedback circuit is not required establish a bridge Dual channel control with feedback circuit Fig 20 Suitable f...

Page 8: ...fety monitoring module for emergency stop circuits guard door monitoring magnetic safety switches and AOPD s Harmonised EC Directives 2006 42 EC EC Machinery Directive 2004 108 EC EMC Directive Person...

Reviews: