Operating instructions

Safety-monitoring module

SRB 401LC

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages resulting 

from the use of unauthorised spare parts or accessories

For safety reasons, invasive work on the device as well as arbitrary  

repairs, conversions and modifications to the device are strictly  

forbidden; the manufacturer shall accept no liability for damages  

resulting from such invasive work, arbitrary repairs, conversions  

and/or modifications to the device

The safety-monitoring module must only be used when the enclosure is 

closed, ie with the front cover fitted

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB 401LC

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained

2.2  Special versions

For special versions, which are not listed in the order code below 21, 

these specifications apply accordingly, provided that they correspond to 

the standard version

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are de-

signed for fitting in control cabinets They are used for the safe evaluation 

of the signals of positive break position switches for safety functions on 

sliding, hinged and removable safety guards as well as emergency stop 

control devices

The safety function is defined as the opening of the enabling circuits 

13-14, 23-24, 33-34 and 43-44 when the inputs S11 - S12 are opened 

or when the supply voltage A1 and A2 is disconnected The safety- 

relevant current paths with output contacts 13-14, 23-24, 33-34 and  

43-44 meet the following requirements under observation of a PFH value 

assessment (also refer to “Requirements of DIN EN ISO 13849-1“):

– Control category 3 - PL d to DIN EN ISO 13849-1 

– SIL 2 to DIN EN 61508-2 

–  SILCL 2 to DIN EN 62061  

(meets the requirements of control category 3 to DIN EN 954-1)

To determine the Performance Level (PL) of the entire safety function 

(eg sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 

relevant components is required

2.4  Technical data

General data:

 

Standards:

 

IEC/EN 60204-1, EN 60947-5-1; 

EN ISO 13849-1, IEC 61508

Climatic resistance:

 

EN 60068-2-78

Mounting:

 

Snaps onto standard DIN rail to EN 60715

Terminal designations:

 

EN 60947-1

Material of the housings:

 

glass-fibre reinforced 

thermoplastic, ventilated

Material of the contacts:

 

AgSnO, self-cleaning, positive drive

Weight:

 

190 g

Start conditions:

 

Automatic or start button

Feedback circuit (Y/N):

 

yes

ON delay with reset button:

 

typically 15 ms

Drop-out delay in case of emergency stop:

 

typically 20 ms

Drop-out delay on "supply failure":

 

typically 30 ms

bridging in case of voltage drops:

 

typically 20 ms

Mechanical data:

 

Connection type:

 

Screw connection

Cable sections:

 

0,25 … 2,5 mm

2

Pre-wired cable:

 

rigid or flexible

Tightening torque for the terminals:

 

0,6 Nm

With removable terminals (Y/N):

 

Nein

Mechanical life:

 

10 million operations

Electrical lifetime:

 

Derating curve available on request

Resistance to shock:

 

30 g / 11 ms

Resistance to vibrations to EN 60068-2-6:

 

10 … 55 Hz, 

amplitude 035 mm

Ambient conditions:

 

Ambient temperature:

 

−25 °C … +60 °C

Storage and transport temperature:

 

−40 °C … +85 °C

Protection class: 

Enclosure: IP40

Terminals: IP20 

Clearance: IP54

Air clearances and creepage  

 

distances to IEC/EN 60664-1:

 

4 kV/2 (basic insulation)

EMC rating:

 

conforming to EMC Directive

Electrical data:

 

Contact resistance in new state:

 

max 100 mΩ

Power consumption:

 

max 2,7 W / 5,0 VA

Rated operating voltage U

e:

 

24 VDC –15%/+20%, 

residual ripple max 10%; 

24 VAC –15%/+10%

Frequency range:

 

50 / 60 Hz

Max fuse rating of the operating voltage: 

 

internal T 05 A

Monitored inputs:

 

Short-circuit recognition (Y/N):

 

refer to chapter 81

Wire breakage detection (Y/N):

 

Yes

Earth leakage detection (Y/N):

 

Yes

Number of NO contacts:

 

0

Number of NC contacts:

 

1

Cable length

1500 m mit 1,5 mm

2

2500 m mit 2,5 mm

2

Conduction resistance:

 

max 40 Ω

Outputs:

 

Number of safety contacts:

 

4

Number of auxiliary contacts:

 

1

Number of signalling outputs:

 

0

Max switching capacity of the safety contacts:

 

13 - 14; 23 - 24; 33 - 34, 43 - 44:  

max 230 V, 6 A ohmic (inductive in case of  

suitable protective wiring); min 10 V / 10 mA,  

residual current at ambient temperature  

up to 45°C: 24 A , 60°C: 16 A

Switching capacity of the auxiliary contacts:

 

51 - 52: 24 VDC / 2 A

Protection of the safety contacts:

 

external (I

k

 = 1000 A) to 

EN 60947-5-1, Safety fuse 10 A gl,  

8 A quick blow, 6 A slow blow

 

Fuse rating for the auxiliary contacts:

 

external (I

k

 = 1000 A) to 

EN 60947-5-1, Safety fuse  

2,5 A quick blow, 2 A slow blow

Utilisation category to EN 60947-5-1:

 

AC-15: 230 VAC / 3 A

DC-13: 24 VDC / 2 A

Dimensions H × W × D:

 

100 × 225 × 121 mm

The data specified in this manual is applicable when the component is 

operated with rated operating voltage U

e

 ± 0%

.

2.5  Safety classification

Standards:

 

EN ISO 13849-1, IEC 61508, EN 60947-5-1

PL:

 

up to d

Control category:

 

up to 3

PFH value:

 

≤ 2,00 × 10

-7

/h

SIL:

 

up to 2

Service life:

 

20 years

The PFH value of 200 × 10

-7

/h applies to the combinations of contact 

load (current through enabling contacts) and number of switching 

cycles (n

op/y

) mentioned in the table below