1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety-monitoring module must be exclusively used in accordance 

with the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications. There 

are no residual risks, provided that the safety instructions as well as 

the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  

the safety-monitoring module, personal hazards or damage  

to machinery or plant components cannot be excluded.  

The relevant requirements of the standards ISO 14119 and 

EN ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The safety relay module is to be operated in an area in which access by 

personnel is restricted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB-E-301MC-

No. Option

Description

Plug-in screw clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 2.5 mm²;  

fine wire with ferrule: 0.25 … 2.5 mm²

CC

Plug-in cage clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 1.5 mm²;  

fine wire with ferrule: 0.25 … 1.5 mm²

(Signal contact 41/42, normally-closed contacts parallel)

SRB-E-301MC20-

No. Option

Description

Plug-in screw clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 2.5 mm²;  

fine wire with ferrule: 0.25 … 2.5 mm²

CC

Plug-in cage clamps: single wire (rigid)  

or fine wire (flexible): 0.2 … 1.5 mm²;  

fine wire with ferrule: 0.25 … 1.5 mm²

(Signal contact 41/42, normally-closed contacts in series)

Only if the action described in these operating instructions is 

carried out correctly will the safety function be safeguarded, 

including compliance with the Machinery Directive.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 

designed for fitting in control cabinets. They are used for the safe 

evaluation of the signals of positive break position switches or safety 

sensors for safety functions on sliding, hinged and removable safety 

guards as well as emergency stop control devices, safety solenoid 

switches and AOPD's.

The safety function is defined as deactivating outputs 13/14, 23/24, 

33/34 when inputs S12 and/or S22 are opened. Taking account of a 

PFH value assessment, the safety-relevant current paths meet the 

following requirements (see also chapter 2.6 “Safety classification”):

• Control category 4 - PL e to ISO 13849-1  

• SIL 3 to IEC 61508  

• SILCL 3 to EN 62061

To determine the Performance Level (PL) to ISO 13849-1 of the entire 

safety function (e.g. sensor, logic, actuator), an assessment of all 

relevant components is required.

The entire concept of the control system, in which the 

safety component is integrated, must be validated to the 

relevant standards.

2.4  Technical data

General data 

Standards:

 

EN 60204-1, IEC 60947-5-1; ISO 13849-1,  

IEC 62061, IEC 61508

EMC rating: 

 

to EMC Directive

Air clearances and creepage distances:

 

to IEC 60664-1

Mounting:

 

standard rail in accordance with IEC 60715

Terminal designations:

 

IEC 60947-1

Summary of Contents for SRB-E-301MC

Page 1: ...nctions Warning Failure to comply with this warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified...

Page 2: ...an area in which access by personnel is restricted 2 Product description 2 1 Ordering code This operating instructions manual applies to the following types SRB E 301MC No Option Description Plug in s...

Page 3: ...ta Connection type refer to 2 1 Cable section refer to 2 1 Connecting cable rigid or flexible Tightening torque for the terminals 0 5 Nm Material of enclosure glass fibre reinforced thermoplastic vent...

Page 4: ...he product is installed must meet the provisions laid down in the paragraph Electromagnetic Compatibility EMC of DIN EN 60204 1 4 2 Coding of connecting terminals 5 Operating principle and settings 5...

Page 5: ...e on Position 1 Ready for application 1 Lights up Lights up Lights up Change SRB E application Switch off operating voltage Select desired application 2 Switch operating voltage on Ready for applicati...

Page 6: ...e SRB E safety monitoring module is only admitted when the requirements of the standard IEC 60947 5 3 are observed As the technical data are regarded the following minimum requirements must be met Swi...

Page 7: ...meaning of IEC EN 60204 1 paragraph 9 2 5 4 2 the operating mode automatic start is only restrictedly ad missible In particular any inadvertent restart of the machine must be prevented by other suitab...

Page 8: ...the machine The setting report must be available whenever a safety check is performed Company The safety monitoring module is used in the following machine Machine n Machine type Module n Configured...

Page 9: ...ereich Energie Textil Elektro Medienerzeugnisse der Deutschen Gesetzlichen Unfallversicherung e V DGUV Gustav Heinemann Ufer 130 50968 K ln Deutschland ID n 0340 EC prototype test certificate ET 18044...

Page 10: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: