background image

3

SRB-E-301MC

Operating instructions

Safety-monitoring module

EN

Electrical characteristics: 

Rated operating voltage U

e

24 VDC –15% / +20%,  

residual ripple max. 10% 

24 VAC –15% / +10%

Frequency range:

 

50 Hz/60 Hz

Power consumption:

 

3.4 W, 8.5 VA

Fuse rating for the operating voltage:

 

internal fuse,  

tripping current > 1A

Insulation values in accordance with IEC 60664-1: 

 

Rated insulation voltage U

i

:

 

 

- Safety contacts:

 

250 V 

Rated impulse withstand voltage U

imp

:

 

 

- Safety contacts 13-14, 23-24, 33-34:

 

4 kV 

Overvoltage category:

 III 

Degree of pollution:

 2

Pull-in delay:

 

< 120 ms

Drop-out delay in case of "emergency stop":

 

< 10 ms

Drop-out delay on "supply failure":

 

< 50 ms

Bridging in case of voltage drops: 

 

typ. 40 ms

Control current circuits/inputs: 

Inputs S12, S22:

 

24 VDC/10 mA

Inputs X2:

 

24 VDC/10 mA

Cable length:

 

1500 m with 1.5 mm²;  

2500 m with 2.5 mm² 

Conduction resistance:

 

max. 40 Ω

Relay outputs: 

Switching capacity of the safety contacts:

 

13-14, 23-24, 33-34:  

max. 250 VDC, 6 A ohmic,  

min. 10 VDC / 10 mA  

(Derating see 2.5)

Fuse rating of the safety contacts: 

 

external (I

k

 = 1000 A)  

to IEC 60947-5-1  

Safety fuse 10 A quick blow, 6 A slow blow

Utilisation category to IEC 60947-5-1:

 

DC-13: 24 V / 4 A  

AC-15: 230 V / 4 A

Switching capacity of the auxiliary contacts:

 

41-42: 24 VDC / 1 A

Fuse rating for the auxiliary contact:

 

safety fuse  

1.5 A quick blow, 1 A slow blow

Electrical life:

 

refer to 2.5

Mechanical life:

 

10 million operations

S

afety contact values:

 

resistance max. 100 mΩ, AgNi, 

 

self-cleaning, positive action

Max. switching cycles / minute:

 20

Inductive consumers:

 

Provision should be made  

for a suitable protection circuit.

Mechanical data: 

Connection type:

 

refer to 2.1

Cable section:

 

refer to 2.1

Connecting cable:

 

rigid or flexible

Tightening torque for the terminals:

 

0.5 Nm

Material of enclosure:

 

glass-fibre reinforced thermoplastic, ventilated

Weight:

 

175 g

Ambient conditions: 

Ambient temperature:

 

–25°C … +60°C  

(non condensing)

Storage and transport temperature:

 

–40°C … +85°C  

(non condensing)

Protection class:

 

Enclosure: IP40,  

Terminals: IP20,  

Clearance: IP54

Resistance to shock:

 

30 g / 11 ms

Resistance to vibrations 

  

to IEC 60068-2-6:

 

10 ... 55 Hz, amplitude 0.35 mm

Altitude:

 

max. 2,000 m

The data specified in this manual apply for operation of equipment with 

rated operating voltage U

e

 ±0%.

2.5  Derating / electrical lifespan of safety contacts

No derating with individual installation of modules.

Derating on request if several modules are installed one after the 

other without spacing and with maximum output load and ambient 

temperatures.

Electrical life of the safety contacts

DC13 24V

AC15 230V

AC1 230V

DC1 24V

10.000.000

1.000.000

100.000

10.000

0           1           2            3           4           5            6           7            8           9

Operations

Contact load in amperes

2.6  Safety classification 

2.6.1 Classification of relay output

Standards:

 

ISO 13849-1, IEC 61508, IEC 62061

PL:

 e

Control Category:

 4

DC:

 high

CCF:

 

> 65 points

PFH

D

:

 

≤ 6.0 x 10

-9

 / h

PFD

avg

:

 

≤ 4.0 x 10

-4

SIL:

 

suitable for SIL 3 applications

Service life:

 

20 years

The PFH value of 6.0 × 10

-9

/h applies to the combinations of contact 

load (current through enabling contacts) and number of switching 

cycles (n

op/y

) mentioned in the table below. At 365 operating days per 

year and a 24-hours operation, this results in the below-mentioned 

switching cycle times (t

cycle

) for the relay contacts.

Diverging applications upon request.

Contact load

n

op/y

t

cycle

20 %

880,000

0.6 min

40 %

330,000

1.6 min

60 %

110,000

5.0 min

80 %

44,000

12.0 min

100 %

17,600

30.0 min

Summary of Contents for SRB-E-301MC

Page 1: ...nctions Warning Failure to comply with this warning notice could lead to physical injury and or damage to the machine Content 1 About this document 1 1 Function 1 1 2 Target group authorised qualified...

Page 2: ...an area in which access by personnel is restricted 2 Product description 2 1 Ordering code This operating instructions manual applies to the following types SRB E 301MC No Option Description Plug in s...

Page 3: ...ta Connection type refer to 2 1 Cable section refer to 2 1 Connecting cable rigid or flexible Tightening torque for the terminals 0 5 Nm Material of enclosure glass fibre reinforced thermoplastic vent...

Page 4: ...he product is installed must meet the provisions laid down in the paragraph Electromagnetic Compatibility EMC of DIN EN 60204 1 4 2 Coding of connecting terminals 5 Operating principle and settings 5...

Page 5: ...e on Position 1 Ready for application 1 Lights up Lights up Lights up Change SRB E application Switch off operating voltage Select desired application 2 Switch operating voltage on Ready for applicati...

Page 6: ...e SRB E safety monitoring module is only admitted when the requirements of the standard IEC 60947 5 3 are observed As the technical data are regarded the following minimum requirements must be met Swi...

Page 7: ...meaning of IEC EN 60204 1 paragraph 9 2 5 4 2 the operating mode automatic start is only restrictedly ad missible In particular any inadvertent restart of the machine must be prevented by other suitab...

Page 8: ...the machine The setting report must be available whenever a safety check is performed Company The safety monitoring module is used in the following machine Machine n Machine type Module n Configured...

Page 9: ...ereich Energie Textil Elektro Medienerzeugnisse der Deutschen Gesetzlichen Unfallversicherung e V DGUV Gustav Heinemann Ufer 130 50968 K ln Deutschland ID n 0340 EC prototype test certificate ET 18044...

Page 10: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: