1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages resulting 

from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re

-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device.

2  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB NA-R-C.39/ST2

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are 

designed for fitting in control cabinets. They are used for the safe 

evaluation of the signals of positive break position switches for safety 

functions on sliding, hinged and removable safety guards.

The safety function is defined as the opening of enabling circuits 13-14, 

23-24 and 33-34 when the inputs T11-T12 and/or T11-T22 are opened. 

The safety-relevant current path with output contact 13-14, 23-24 and 

33-34 meets the following requirements under observation of a B

10d

 

value assessment (also refer to “Requirements of DIN EN ISO 13 849-1“):

– Control category 4 - PL e to DIN EN ISO 13849-1

 

– SIL 3 to DIN EN 61508-2

 

–  SILCL 3 to DIN EN 62061 

 

(meets the requirements of control category 4 to DIN EN 954-1)

To determine the Performance Level (PL) of the entire safety function 

(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 

relevant components is required.

2.4  Technical data

General data

Standards:

IEC/EN 60204-1, EN 60947-5-1; 

 

EN ISO 13849-1, IEC 61508

Climate resistance:

EN 60068-2-78

Fixing:

Snaps onto standard DIN rails 

 

to DIN EN 60715

Terminal designations:

EN 60947-1

Material of the enclosure:

glass-fibre, thermoplastic

Material of the contacts:

AgSnO, self-cleaning, positive drive

Weight:

320 g 

Start conditions:

Automatic

Feedback circuit (Y/N):

Yes

Pull-in delay with  

automatic start:

on request

Pull-in delay with  

reset button:

typ. 200 ms

Drop-out delay in case  

of emergency stop:

typ. 20 ms

Drop-out delay on  

"supply failure":

on request

Mechanical data

Connection type:

Screw terminals

Cable section:

min. 0,25 mm

2

 / max. 2,5 mm

2

Connecting cable:

rigid or flexible

Tightening torque for 

 

the terminals:

0.6 Nm

With removable terminals (Y/N): No

Mechanical life:

10 million operations

Electrical life:

Derating curve available on request

Resistance to shock:

10 g / 11 ms

Resistance to vibrations  

to EN 60068-2-6:

10 ... 55 Hz, amplitude 0.35 mm

Ambient conditions

Ambient temperature:

–25°C … +45°C

Storage and transport  

temperature:

–40°C … +85°C

Protection class:

Enclosure: IP 40

Terminals: IP 20

Wiring compartment: IP 54

Air clearances and creepage 

distances to IEC/EN 60664-1:

4 kV/2 (basic insulation)

EMC rating:

to EMC Directive

Electrical data

Contact resistance in new state: max. 100 mΩ

Power consumption:

max. 2.7 W / 2.7 VA

Rated operating voltage U

e

:

24 VDC –15% / +20%, 

 

residual ripple max. 10%

24 VAC: –15% / +6%

Frequency range:

50 Hz / 60 Hz

Max. fuse rating of  

the operating voltage:

F1: internal electronic fuse, 

 

tripping current > 0.5 A, 

 

reset after approx. 1 sec.

Monitored inputs

Cross-wire detection (Y/N):

No

Wire breakage detection (Y/N):

Yes

Earth leakage detection (Y/N):

Yes

Number of NO contacts:

0

Number of NC contacts:

2

Cable lengths:

– 1,500 m = 1.5 mm²

 

– 2,500 m = 2.5 mm²

 

1-channel 

2-channel without cross-wire 

 

short detection

Conduction resistance:

max. 40 Ω

Outputs

Number of safety contacts:

3

Number of auxiliary contacts:

0

Number of signalling outputs:

1

Switching capacity of  

the safety contacts:

13-14 / 23-24 / 33-34:

max. 230 V, 6 A ohmic (inductive in 

case of appropriate protective wiring)

DC-13: 24 V / 2 A;

AC-15: 230 VAC / 3 A

Switching capacity  

signalling output Y1:

L14: 100 mA slow blow

Fuse rating of the  

safety contacts:

6.3 A slow blow 

Utilisation category 

 

to EN 60947-5-1:

AC-15 / DC-13: EN 60947-5-1

Dimensions (H/W/D):

83 mm × 45 mm × 140 mm

The data specified in this manual is applicable when the component is 

operated with rated operating voltage U

e

 ±0%.