Operating instructions

Solenoid interlock

TZM/TZF SPEZ

EN

3.  Mounting

3.1  General mounting instructions

Three mounting holes are provided for fixing the enclosure. The 

solenoid interlock is double insulated. The use of an earth wire is not 

authorised. The solenoid interlock must not be used as an end stop. 

Any mounting position. The components however must be mounted 

so that the opening of the actuating head is protected against the 

penetration of dirt (e.g. sand, dust, chips). In case of painting activities, 

the components must be covered.

In all ...CHI versions, the factory set actuating direction must 

not be changed. If the actuating direction of these versions is 

modified, the holding force F no longer is guaranteed.

If another actuating direction is desired, the four screws of the actuating 

head must be loosened. Turn the actuating head in the desired direction 

and retighten the screws (tightening torque 0.5 Nm). The default screws 

installed in the actuating head can be replaced with the supplied 

tamperproof screws.

For power-to-unlock devices (TZF...), the actuator must 

be inserted when the actuating head is turned.  Any 

non-observance of this prescription could result in the 

components being damaged.

The safety component and the actuator must be permanently 

fitted to the safety guards and protected against displacement 

by suitable measures (tamperproof screws, gluing, drilling, 

pinning).

Please observe the remarks of the standards ISO 12100, 

EN 953 and ISO 14119.

When used in ambient temperatures > 40°C, the solenoid 

interlock must be protected against contact with inflammable 

materials or inadvertent personal contact.

3.2  Dimensions

All measurements in mm.

TZ…

129

95

125

15

5,5

65

79

92

,5

7,5

41

15

26

5

5,

04

37

,5

22

TZ…CHI

37,

5

95

15

5

5,5

9

50,

5

13

65

79

7

7,5

102,5

125

129

15

26

41

4.  Rear side Electrical connection

4.1  General information for electrical connection

The electrical connection may only be carried out by 

authorised personnel in a de-energised condition.

If the risk analysis indicates the use of a monitored interlock 

they are to be connected in the safety circuit with the 

contacts indicated with the symbol  .