Elevator positioning system USP 30 / 100
Electromagnetic Compatibility (EMC)
We would like to point out that the USP receiver is an electronic
device which may be influenced by external magnetic fields.
You must avoid a close distances of units that may influence
the electromagnetic compliance of the receiver. These are
inverters, motors or others. You may contact us for further
information.
Electromagnetic compatibility of the USP according
IEC 61000-6-2 and EN 12016.
Installation of the USP
Tools required for installation
• Side cutter
• Cross-head screwdriver
• Socket wrench and sockets, SW 10 + SW 13
Location
The location of the USP receiver should be chosen close to the
machine room or the lift controller.
Examples:
• If you have an hydraulic elevator with the machine room adja-
cent to the pit you should install the USP receiver in the pit.
• If you have a cable lift with a machine room at the shaft head
you should mount the USP receiver in the shaft head.
• If the application of the USP is in a machine room less lift you
should care that no other components like motors or inverters
will influence the electromagnetic compatibility.
As there are many possibilities to design a lift we cannot define
the optimal position for the installation in every case. Special
local conditions will require different mounting positions. Please
contact us for further information.
Danger of breakage!
Never install the upper and lower
system elements of the USP within
the area of the maximum possible
travel way of the elevator cabin, the
counterweight or the hydraulic ram!
If it is installed incorrectly, the USP
could be destroyed by the moving
elevator cabin.