47
Elevator positioning system USP 30 / 100
Take the swing protection from the USP packing box.
Attach the swing protection to the C-profile with the fasteners
provided. Align the swing protection so that the signal wire runs
vertically through the swing protection after installation of the
damper.
Please combine damper and signal wire. Follow steps
4
and
5
.
Note in the installation, that there must be a clearance
of min. 15 cm between the damper and the swing
protection.
Align the signal wire centrally along the length of the damper
mat. Ensure that the wire runs straight out of the damper. Now
fix the second half of the damper, as illustrated. Hold the two
halves of the assembled damper together by hand.
Follow this installation step very carefully. Signal wire and
damper housing must not touch as this will result
in a reflection of the ultrasonic signal and will therefore
influence the function of the USP.
Fasten the two halves of the damper together, using the captive
screws.
10
11
USP_Montage_GB.indd 47