Elevator positioning system USP 30 / 100
Cutting the signal wire to length
Stop the travel at the shaft pit. First pull out the signal
wire by hand until the end of the wire touches the ground
on the shaft pit after it is cut off. Then cut the signal wire
at the mounting device and allow the wire to fall
between the elevator cabin and the shaft wall onto the
ground.
Travel upwards in ”inspection travel” mode until you can
get into the shaft pit.
Attach the second C-profile to the guiding rail with the mounting
brackets. The C-profile must be installed outside the maximum
travel way of the elevator cabin or of any other moving parts.
Ensure that you leave a minimum clearance of at least 80 cm
between the floor of the shaft and the C-profile. It is necessary
that the lower damper can hang freely from the signal wire.
+ 5 m
9
10
Danger of injury from the signal
wire springing back!
The spring force and sharp
ends can cause injury.
Wear protective glasses!
USP_Montage_GB.indd 54