4 Maintenance and servicing
20
SCHMIDT
®
ServoPress 605-660
– V1.1
Starting the press system
Switch on the press system with the main switch on the switch cabinet.
After restarting the system, a message is displayed whether grease has
been refilled.
If you acknowledge the message by pressing the "Yes" button, the press
system is again ready for operation.
If you acknowledge the message by pressing the "No" button, you must
repeat the entire process.
CAUTION
Damage to the press
If the message was acknowledged by pressing the "Yes" button but no
grease has been filled, you will damage the press. Increased friction will
result in the destruction of the spindle and the spindle bearing.
Fill the grease reservoir as soon as the system issues the request.
Replace the grease cartridge as soon as the system issues the
request!
Use only full grease cartridges for replacement purposes.
4.5 Troubleshooting
Fundamental functions are automatically monitored by the press. A flashing
signal on the ring-shaped status display of the process data acquisition
indicates the various operating states.
Figure 13: Status display (example)
1
Status display "X1"
2
Status display "X2"
3
Status display "X3"
24 V DC / EtherCAT inactive
INIT / No LINK
INIT / LINK OK & No ACT
INIT / LINK OK & ACT OK
Pre-Operational
Safe-Operational
Press ready
Process data acquisition
RangeCalc
Press not referenced
FW-Update (Bootloader active)
FW-Update (FoE in FW active)