I/2
UNM Base / CPM Base
GB
Table of contents - Part 1
1.1 Scope of delivery
A202002 / A211002 / A212002 / A711002 /
A711003:
– Compressor with instruction manual
A213002 / A214002 / A712002 / A712012 /
A713002 / A714002 / A715002 / A715102:
– Compressor with instruction manual
– Documents accompanying compressed air
vessel
1.2 Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
The compressor must
not
be used in poten-
tially explosive areas. Combustible, caustic
or toxic gases must
not
be sucked in!
1.3 Technical data
see Fig. 1a
1.4 Components
1.5 Maintenance
1.5.1 Cleaning the intake filter
1. Unscrew the intake filter. (Fig. 5a)
2. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
3. Screw the intake filter back on.
A711003:
1. Loosen the screws and open the housing
as shown in Fig. 5a.
2. Pull out the filter insert (Fig. 5a).
3. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
4. Insert the filter insert.
5. Close the housing and tighten the
screws.
1.6 Vessel inspections
A202002 / A211002 / A212002 / A711002 /
A711003:
No inspections are specified for the ves-
sels.
We recommend that a "qualified person" per-
form a pressure test on the vessel, depend-
ing on its rate of utilisation, after 10 years in
accordance with the Ordinance on Industrial
Safety and Health. Contact any of our service
partners.
The statutory specified inspections must
be arranged in accordance with the appli-
cable regulations of the respective coun-
try in which the vessel is used.
A213002 / A214002 / A712002 / A712012 /
A713002 / A714002 / A715002 / A715102:
Compressor with type test:
Inspection is
not required prior to commissioning.
Type identification: see compressor type
plate
We recommend that a "qualified person" per-
form a pressure test on the vessel, depend-
ing on its rate of utilisation, after 10 years in
accordance with the Ordinance on Industrial
Safety and Health. Contact any of our service
partners.
It is essential to retain vessel documents
included in the delivery (= certification
documents) for the entire service life of
the vessel. The statutory specified inspec-
tions must be arranged in accordance
with the applicable regulations of the re-
spective country in which the vessel is
used.
1.1
Scope of delivery ......................
2
1.2
Conventional use ......................
2
1.3
Technical data ..........................
2
1.4
Components.............................
2
1.5
Maintenance.............................
2
1.6
Vessel inspections .....................
2
01 Compressor unit
02 Intake filter
03 Oil dipstick
04 Oil drain screw
06 Pressure pipe
07 Check valve
08 Vessel
09 Condensate drain valve
10 Pressure switch with ON/OFF switch
11 Safety valve
12 Pressure gauge (vessel pressure)
13 Pressure gauge (working pressure)
14 Electric motor
16 V-belt
17 Belt guard grating
18 Pressure reducer
19 Quick-action coupling
Summary of Contents for A202002
Page 2: ......
Page 7: ...1a...
Page 16: ...I 8 UNM Base CPM Base RUS 10...
Page 59: ...UNM Base CPM Base II 43 RUS 2 7 2 2002 96 EG 2 8 A B C A D 2 4 4...
Page 60: ...II 44 UNM Base CPM Base RUS E 2 6 3 F G 2 6 9 H 2 6 3 E I J...
Page 61: ...UNM Base CPM Base II 45 RUS 2 9 K L 2 6 8...
Page 66: ......
Page 67: ......