II/8
UNM Base / CPM Base
GB
• Be calm and focused and ensure proper
operation.
• Protect yourself and other persons, ani-
mals, property, and the environment by
taking the necessary protective measures
and being trained in use of the devices to
prevent harm to your health, property
damage, financial loss, environmental
harm or risk of accident.
• Repairs may be carried out only by Schnei-
der Druckluft GmbH or its approved service
partners.
• Observe the Instruction Manual for ves-
sels!
•
Prohibited:
Manipulations, use for pur-
posed other than those intended; tempo-
rary repairs; compressing other energy
sources; removing or damaging safety
equipment; use in case of leaks or mal-
functions; not using original spare parts;
exceeding the specified permitted final
compression pressure; working without
safety equipment; transporting the unit,
maintaining it, repairing it or leaving it un-
supervised while pressurised; using other/
incorrect lubricants; smoking; open flame;
removing stickers.
•
Prohibited:
Releasing compressed air via
the condensate drain valve; hanging the
unit on crane ropes; shutting down or
starting up without actuated locking brakes
of guide roll (item 38).
2.4 Commissioning
2.4.1 Transport
• Check the handle for secure fit.
• Vessel depressurised.
• In the vehicle: transport the compressor in
an upright position, secure and protect it.
2.4.2 Conditions at the installation lo-
cation
• Rooms: as dust-free as possible, dry, well
ventilated.
• Installation surface: flat, horizontal.
2.4.3 Before first use
1. Carry out a visual inspection.
2. Check the electrical connection.
3. Check the oil level (see Chap. 2.6.4).
For units with attached oil dipstick, re-
place with sealing plug in unit and fill with
oil.
2.4.4 Electrical connection
• The mains voltage must match that speci-
fied on the rating plate.
• Electric protection according to technical
data.
When using extension cords: cable cross-
section: min. 2.5 mm²; max. cable
length:10 m.
2.4.5 Checking/changing the rotation
direction
For three-phase compressors:
1. Check the rotation direction each time
the power plug is plugged in: switch on
the compressor, observe it and switch it
off again if the rotation direction is incor-
rect.
2. Unplug the power plug.
3. Three-phase plug with phase inverter:
press it in and rotate it by 180°. (Figure
2a)
Three-phase plug without phase invert-
er: reverse the phases in the plug.
Repeat step 1.
4. If direction of rotation has not changed:
contact service partner.
2.4.6 Filling the mist oiler
For compressors with mist oiler:
1. Depressurise the compressor/vessel.
2. Unplug the power plug.
WARNING
Burn hazard on the motor, unit, check
valve, connecting hose/pressure pipe
and from hot oil!
Wear safety gloves!
WARNING
Hearing damage from noise during op-
eration!
Wear ear protection!
WARNING
Damage to the connexion cable!
Protect it from sharp edges, oil and heat!
Grasp the plug and unplug it from the
power outlet!
CAUTION
Risk of crushing!
Never actuate the guide roll locking brake
manually but always with your foot.
Summary of Contents for A202002
Page 2: ......
Page 7: ...1a...
Page 16: ...I 8 UNM Base CPM Base RUS 10...
Page 59: ...UNM Base CPM Base II 43 RUS 2 7 2 2002 96 EG 2 8 A B C A D 2 4 4...
Page 60: ...II 44 UNM Base CPM Base RUS E 2 6 3 F G 2 6 9 H 2 6 3 E I J...
Page 61: ...UNM Base CPM Base II 45 RUS 2 9 K L 2 6 8...
Page 66: ......
Page 67: ......