1.6 Commissioning
1.6.1 Before first use
L
Replace the sealing plug with the oil dip-
stick (item 03) and fill with compressor
oil. For oil quantity, see "Technical data"
chapter.
1.7 Compressor inspections
This compressor is subject to a type approval
inspection. As a result, inspections by an au-
thorised expert prior to commissioning are
no longer necessary
. The prototype identi-
fication code is located on the compressor
specification plate.
We recommend that a "qualified person"
perform a pressure test on the vessel after
10 years, depending on general levels of
wear and tear.
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
L
The papers accompanying the vessel are
approval documents and must be kept
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.
09 Condensate drain valve
10 Pressure switch with ON/OFF switch
11 Safety valve
12 Pressure gauge (vessel pressure)
13 Pressure gauge (working pressure)
14 Electric motor
18 Filter pressure reducer
19 Quick-action coupling (clean, regu-
lated compressed air)
Summary of Contents for T100102
Page 2: ...1a 1b 01 06 12 13 14 07 19 11 18 08 10 02 03 04 09...
Page 3: ...5a 4a 6a 7a max min...
Page 73: ...UNM II 53 RUS 1 2 3 1 X X X X X X X X X...
Page 79: ...UNM II 59 RUS 2 8 X B X C X X X A X D X 2 4 4...
Page 80: ...II 60 UNM RUS E X X X X 2 6 5 X X F X G X 2 6 11 X H X 2 6 5 X E I X X J X X X...