UNM / CPM / ZPM
II/9
GB
2.4.6 Filling the mist oiler
For compressors with mist oiler:
1. Depressurise the compressor/vessel.
2. Unplug the power plug.
3. Unscrew the oil tank from the mist oiler.
(Figure 3a)
Use suitable oil (Art. No. B770000)!
2.4.7 Adjusting the mist oiler
1. Carefully screw the regulating screw
closed using a screwdriver in a clockwise
direction. The screw it open by 1/2 to 1
turn (Figure 3a).
2. During air extraction, oil deposits in the
form of droplets can be seen at the upper
sight glass. Dosing: 1 droplet oil at 300
– 600 l/min air consumption. Readjust If
necessary and check regularly.
2.5 Operation
Do not overload the compressor: do not
exceed the max. number of switching cy-
cles and the ratio of operating time to
standstill!
2.5.1 Insert
Switch on the compressor at the ON/OFF
switch (item 10). The compressor starts up
and switches off automatically at maximum
pressure.
2.5.2 Adjusting the working pressure
1. Pull up the adjustment button on the (fil-
ter) pressure reducer (Figure 4a).
2. Rotate clockwise = pressure is in-
creased. Rotate anticlockwise = pressure
is reduced.
3. Read the set working pressure on the
pressure gauge (item 13).
4. Press the adjustment button down to
lock it in place.
2.5.3 After use
1. Switch off the compressor.
2. Disconnect the power supply.
3. Disconnect plug nipple of air hose from
(safety) quick-action coupling.
4. Clean compressor (Chap. 2.6.2), depres-
surise it (Chap. 2.6.1), transport to stor-
age location (Chap. 2.4.1).
2.6 Maintenance
2.6.1 Before each maintenance task
1. Swtich on the compressor at the ON/OFF
switch (item 10). Disconnect the power
supply.
2. Depressurise the compressor: using the
blow gun, blow out all pressure from the
vessel.
Interval / No later
than
Tasks
See chap.
-- / As needed
Clean compressor
Clean filter insert (FDM)
-- / after each use
Drain condensate from pressure vessel
Drain condensate from FDM
daily / commissioning
Check the oil level, add oil if necessary.
Once after 10 h / --
Check screw connections
-- / Weekly
Check intake filter
50 h / After 6 months
Check V-belt tension (where applicable)
Clean intake filter
Change oil (1st oil change mineral or synthetic oil) 2.6.7
500 h / after 1 year
Change oil (with mineral oil)
Change intake filter
Change check valve and insert
Check screw connections
1,000 h / after 2 years
Change oil (with synthetic oil)
Change V-belts (where applicable)
2,500 h / After 5 years
Change safety valve
Summary of Contents for Universal 170-25 W
Page 3: ...5a 6a 02 7a max min 9a...
Page 4: ......