EN 61000-3-2:2006 

Electromagnetic compatibility (EMC) - Part 3-2: 

 

Limits - Limits for harmonic currents 

 

(equipment input current 16 A per conductor) 

 

(IEC 61000-3-2:2005 + A1:2008 + A2:2009); 

 

German version EN 6100-3-2:2006 + A1:2009 + A2:2009 

 
EN 61000-3-3:2008 

Electromagnetic compatibility (EMC) - Part 3-3: Limits  

 

Part 3-3: Limits -  
Limitation  of  voltage  variations,  voltage  fluctuations  and 
flicker in public low-voltage supply systems for equipment 
with a rated current < 16 A per conductor and not subject 
to a special connection condition. 

 

(IEC 61000-3-3:2008); 

 

German version EN 61000-3-3:2008 

 
EN 61000-6-1:2007 

Electromagnetic  compatibility  (EMC)  -  Part  6-1:  Generic 
standards  -  Immunity  for  residential,  commercial,  and 
light-industrial environments  

 

Immunity  for  residential,  commercial  and  light-industrial 
environments. 

 

(IEC 61000-6-1:2005); 

 

German version EN 61000-6-1:2007 

 
EN 1127-1:2019 

Explosive  atmospheres  -  Explosion  prevention  and  pro-
tection - Part 1: Basic concepts and methodology 

 

 
 
 

 
 
 

 
 

 
 
 

 
 
 

 
 

Rommelsbach 01.04.2021 

 

 

Olav Schnier (Geschäftsführer) 

 

Summary of Contents for 810464

Page 1: ...1 Art Nr 810464 70 kV 50 A...

Page 2: ...Specifications 3 1 3 Product identification 3 1 4 Warranty 4 1 5 Manufacturer 4 2 Guide to these operating instructions 4 3 Intended use 4 3 1 Further notes on hazard prevention 5 4 Structure and ove...

Page 3: ...ers and is de signed for a long service life The modern 21700 Li Ion battery from the SCHNIER Power Series allows flocking for several hours Due to the quick change flap the battery can be changed wit...

Page 4: ...h ftsf hrer Olav Schnier 2 Guide to these operating instructions These operating instructions must be read understood and observed in all points by all persons who are responsible for the equipment On...

Page 5: ...w nests in the applicator during creep currents DANGER Use only approved flock types within the processing specifications When using organic flock cotton artificial silk additional protective mea sure...

Page 6: ...h voltage due to insulation faults DANGER Preventive maintenance to avoid insulation faults Hazard Slipping tripping and falling Description Loose flock on the floor may cause slipping hazard ATTENTIO...

Page 7: ...dren Remove flammable liquids vapors and flammable gas mixtures before start up Do not operate if persons with pacemakers are in the vicinity Do not touch electrodes Store in a dry place protect from...

Page 8: ...4 Structure and overview 4 1 Device overview 1 Pushbutton High Voltage on 2 4 mm socket for ground wire 3 Battery indicator 4 Operating indicator 5 Battery lock 6 Quick change flap 7 Li Ion battery p...

Page 9: ...Operating instructions 810464 BAL DE 210401 Version 01 4 2021 Page 9 of 12 8 High voltage connection 9 Damping resistor encapsulated 10 Applicator with cast electrode 11 Flocking screen 8 9 10 11...

Page 10: ...only be used at your own risk Place the applicator in the lower end of the MINI Flocker Evo and screw it on hand tight Fill with the desired flock fibers and place the appropriate sieve Connect the g...

Page 11: ...of 17 May 2006 on machinery and amending Directive 95 16 EC recast 1 Published in L 157 24 of 09 06 20 2014 30 EU Directive 2014 30 EU of the European Parliament and of the Council of 26 02 2014 on th...

Page 12: ...nd flicker in public low voltage supply systems for equipment with a rated current 16 A per conductor and not subject to a special connection condition IEC 61000 3 3 2008 German version EN 61000 3 3 2...

Reviews: