Hotplate 26060 FB - 26150 FB
STATE March 2010
6
3
Electrical connection
Before connecting please observe indications on rating plate!
Observe VDE-regulations and regulations of your local power supplier!
Connected load 1 x 10 A
Fuse protection 0,33 kW - 2 kW
Voltage
IN AC 230 V
-
Special voltage upon demand
-
Device is delivered with a helix cable of 2m length. E.g. type 3 x 1H05RN3G
-
On site:
provide accessible, all pole separation device
with contact distance of min. 3mm
.
EG regulations:
EMV 89/336
NSR 73/23
CE regulations:
93/68
3.1 Indication of particular kinds of danger
3.2 Electrical energy
Use only genuine fuses with prescribed strength of current! In case of
disturbances
in power
supply
switch off device immediately!
Works at electrical installations or operational means have to be carried out by authorised electric
under guidance and supervision of authorised electricians or trained persons according to Electro
mechanical rules. During works of inspection, maintenance and repair at the device or
components of installation, voltage has to be switched off. Check parts first if they are powerless,
then earth and short out. Insulate adjacent parts under tension!
Electrical equipment of a device has to be checked regularly. Faults, such as loose connections
resp. burned cables have to be removed immediately.
Use only tension-insulated tools!