5.3.1 C
ONTROL PANEL
The hot or cold combiplate can be set and operated via the touch control panel mounted on the front. The
five buttons are used for adjusting settings, switching (between heating or cooling mode), quick choice
between preset values, as well as parameterization. Only press the buttons using a finger or a Touchpen.
ON/OFF button
With this button the device is turned on or off.
When turning it on, the last selected mode starts.
Button
These buttons are for adjusting the temperature.
Button
By pressing the
button, the adjusted tempera-
ture will be shown in the display. To change the
temperature press
and either
or
, to
adjust the temperature accordingly.
Selection button
The button is used to switch between the heating
or cooling mode. The respective preset setpoint is
effective for control.
Display hot mode
The device is in heating mode.
Display cool mode
The unit is in cooling mode.
Digital display
Shows the actual and by pressing the
button
the target temperature.
ATTENTION!
A change in the preset parameters should only be carried out by customer service.
When switching from heat to cooling mode, the compressor will only start once an actual temperature of
+40° C has been reached.
When turning the device off at a temperature over 40 °C, the ACTUAL temperature and OFF flash alter-
nately in the digital display.