5. Installation | Upper Adapter and frame
Fix the upper adapter to the
cabinet or to the L-console
Use the frame as a measurement
device for the correct height.
Turn the L-shape in a way that
the frame is leaning slightly
inside the cabinet (between 90
and 91
°). At a system height of
1780 this corresponds to 5 - 10
mm.
Start with a first frame flush with the
lower adapter.
The adapter has to be aligned with the front of the frame.
In case of fixation directly to the cabinet, drill and rivet 3 times for
an adapter of 1250 mm. Use 3 rivets Alu
Ø4,8x10.
In case of fixation to the L-console use screws and
nuts M6
Fix the upper part of the frame to the adapter with 3
rivets in the existing holes previewed in the frame.
Use Alu
Rivets Ø4,8x25 on the left and right and in the
middle an Alu
Rivet Ø4,8x10.
Make sure that the adapter is in level to avoid deformation when
riveting. If this is not the case, use a plastic plate to bring it to
contact. Use for example if delivered the plastic plate 2000 x
100 x 2 mm and cut out the size that you need.
Install all frames of a line.
Fix only the upper part as described
on the previous page
Connect the vertical bars with the
tape, which is always on the right side
of a frame
Assure that the frames are properly
aligned