J1034-UV-A/B/E DETECTOR Manual 

 

COMPONENTS, PARTS, REFERENCE 

List of additional parts

 

Order No 

Parts 

Description 

103401 

UV-A 

UV-A radiometer 

103404 

UV-B 

UV-B radiometer 

103406 

UV-E 

UV-E radiometer (erythemally weighted) 

103410 

UV-AB 

UV-AB radiometer 

103411 

UV-A/UV-E 

UV-A and UV-E radiometer (dual band) 

103412 

UV-A/UV-B 

UV-A and UV-B radiometer (dual band) 

103402 

UV-10m 

10 m weatherproof Cable connection for UV radiometers 

105102 

Power 12V 

Plug in power supply 12VDC/2A 

105104 

DETECTORBASE2 

Detector base plate to mount on UVA detector. Including 
spirit level. 

105103 

DETECTORBASE  Detector base to hold detector in selected place 

103304 

J1033-
SHADOWRING 

Shadow 

ring 

for 

manually 

alignment. 

To  measure  diffuse 
part of solar radiation 

100229 

Circlevel1 

Circular spirit level 

Each UV-xx detector is delivered with 5 m weatherproof Cable connection 

References 

[1]  WMO/GAW Report No. 141: Report of the LAP/COST/WMO Intercomparison 

of Erythemal Radiometers, Thessaloniki, Greece, 1999. WMO TD – No. 1051. 

 

[2]  WMO/GAW Report No. 146: Quality Assurance in Monitoring Solar Ultraviolet 

Radiation: the State of the Art. WMO TD – No. 1180. 

 

[3]  WMO/GAW  Report  No.  164:  Instruments  to  measure  Ultraviolet  Radiation, 

Part  2:  Broadband  Instruments  Measuring  Erythemally  Weighted  Solar 
Radiation. WMO TD – No. 1289. 

 

[4] ISO 17166:1999 / CIE S 007/E-1998: Erythema reference action spectrum and 

standard erythema dose. 

 

[5]  Schreder, J., J. Gröbner, A. Los, and M. Blumthaler, 2004: Intercomparison of 

monochromatic  source  facilities  for  the  determination  of  the  relative  spectral 
response of erythemal broadband filter radiometers. Optics Letters, 29(13). 

 

[6]  G. Hülse, J. Gröbner, A. Bais, M. Blumthaler, P. Disterhoft, B. Johnsen, K.O. 

Lantz,  C.  Meleti,  J.  Schreder,  J.M.  Vilaplana  Guerro,  L.  Ylianttila: 
Intercomparison of erythemal broadband radiometers calibrated by seven UV 
calibration  facilities  in  Europe  and  USA.  Atmos.  Chem.  Phys.,  8,  4865-4875, 
2008. 

http://www.atmos-chem-phys.net/8/4865/2008/acp-8-4865-2008.html

 

Summary of Contents for J1034-UV-A

Page 1: ...34 UV A B E DETECTOR USER S MANUAL C M S In g D r Sc h re de r G m b H Lofererstraße 32 A 6322 Kirchbichl Tel 43 0 5332 77056 00 Fax 43 0 5332 77056 14 E Mail info schreder cms com Web www schreder cms com ...

Page 2: ...ake one copy of the software disk for backup purposes The software may not be copied or distributed in any other way No part of this manual may be reproduced or transmitted in any form or by any means electronic optical or mechanical including photocopying and recording or by any information storage and retrieval system without permission in writing from CMS Ing Dr Schreder GmbH ...

Page 3: ...1 WARRANTY 1 CONTACT INFORMATION 1 SAFETY INFORMATION 2 WARNING CAUTION 2 VOLTAGE WARNING 2 GENERAL DESCRIPTION 3 TECHNICAL DATA 3 PIN CONNECTION OF ALL UV DETECTORS 3 RELATIVE SPECTRAL RESPONSE 4 MOUNTING AND ALIGNMENT 5 COMPONENTS PARTS REFERENCE 6 LIST OF ADDITIONAL PARTS 6 REFERENCES 6 ...

Page 4: ...s the appropriate specifications The product warranty is valid only if the product has been installed and used according to the directives provided in this instruction manual CMS shall in no event be liable for incidental or consequential damages arising from the faulty and incorrect use of the product In case of any manufacturing defect the product will be repaired or replaced under warranty Howe...

Page 5: ...ation base should have enough load capacity for the instrument to be mounted Fix the equipment securely Otherwise the instrument may drop due to gale or earthquake which may lead to unexpected accidents Make sure the instrument and the cables are installed in a location where they will not get soaked Voltage Warning Power Supply Make sure to check the power supply voltage and type AC DC before con...

Page 6: ...6 1999 CIE S 007 E 1998 265 315 nm 310 400 nm 280 400 nm See individual detectors Type Single band Dual band Cosine error f2 1 5 Cosine Response 2 5 between 0 and 70 solar zenith angle Measure range 0 0 6 W m 0 5 W m 0 100 W m 0 100 W m 0 100 0 0 5 W m 0 100 0 0 5 W m Signal output 0 5 V on request 0 2 5 V Temperature range 40 C 60 C Temp coefficient 0 1 K Power Supply 9 24 V 0 75mA Time switch on...

Page 7: ...ure 1 Relative Spectral Response of the single band detectors Erythemal weighting function ERY defined ISO 17166 1999 CIE S 007 E 1998 260 280 300 320 340 360 380 400 10 4 10 3 10 2 10 1 10 0 WAVELENGTH nm RELATIVE SPECTRAL RESPONSE ERY UV E AE UV A AE Figure 2 Relative Spectral Response of the dual band detector Erythemal weighting function ERY defined ISO 17166 1999 CIE S 007 E 1998 ...

Page 8: ... to the UV detector The additional available Detectorbase 105303 is a general purpose base plate which fits directly to the J1033 Shadowring 103304 It allows a robust and quick alignment to individual grounds Use the tilting screws to align the detector and control the correct settings with the help of the spirit level After that use the montage screws to fix the detector to the ground Figure 3 UV...

Page 9: ...AW Report No 141 Report of the LAP COST WMO Intercomparison of Erythemal Radiometers Thessaloniki Greece 1999 WMO TD No 1051 2 WMO GAW Report No 146 Quality Assurance in Monitoring Solar Ultraviolet Radiation the State of the Art WMO TD No 1180 3 WMO GAW Report No 164 Instruments to measure Ultraviolet Radiation Part 2 Broadband Instruments Measuring Erythemally Weighted Solar Radiation WMO TD No ...

Reviews: