00-63-030 | DOC-0016143 Rev C | 11 -2019
6/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue
de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to c
hanges without notice.
www.schreder.com
4 x M18
172 N.m
126.9 lb.ft
+1
-0
27
Put in place the column, guiding the
electrical cables to the compartment base.
Fully tighten the nuts following the recommended
torque values.
Check the correct vertical alignment of the pole.
Assemble the top washer and nut. Check and if
necessary correct, the column’s verticality by turning
the leveling nuts, underneath the flange plate.
M18 Nut
Washer
Washer
Flange Plate
M18 Nut
Used for leveling pole
M18 Anchor Bolt
Concrete
Place a levelling nut, plus washer, on each bolt.
5
7
8
Pole should be oriented in a way that performing
any kind of maintenance is easy and safe.
6
FLANGE PLATE MOUNTING
+0.7
-0