1. Safety Instructions
Mounting and installation must be done in accordance with the respective regulations.
The light fitting must be protected against overvoltage, overcurrent, short circuits and other
electrical failures.
The light fitting must be operated in an undamaged condition only.
The light fitting may only be opened if it has been disconnected from the mains supply completely.
Versions with battery box may only be opened after the plug connector of the battery in the battery
box has also been disconnected.
The non-stationary use of the light fitting as well as any other inappropriate usage is prohibited.
The operation of the light fitting is allowed within its assessment thresholds only.
In regard to the minimum and maximum admissible ambient temperature potential sources of cold
and heat (e.g. direct heat or solar radiation, cooling units) have to be considered.
If the light fitting is subject to a special application that is influenced chemically, mechanically,
thermically or electrically or if the light fitting will be subject to any kind of vibrations, it is highly
recommended to consult the Adolf Schuch GmbH before starting the installation.
Every structural modification will cause dangerous situations and consequently the certification of
this light fitting will be null and void. So it is not allowed to drill through the housing for installation
purposes.
Caution - Risk of electrostatic discharge! Fitting to be cleaned with damp cloth only!
In areas with risk of accidental electrostatic charge (e.g. by passing by) the light fitting must
be protected by appropriate measures.
The light fitting is not allowed to be installed in process areas where strong electrical fields
may occur (i.e. HV Sparkling Electrodes or Particle Streams). Reason is to avoid any
electrostatic charge of the light fitting itself.
Replace damaged explosion-proof parts by original spare parts from the Adolf Schuch GmbH only.
LED-reflector with mounted LED-modules and Electronic control gear of this light fitting must be
replaced by A. Schuch GmbH, by a service technician who is instructed from Schuch or by any
other person with equivalent qualification only.
It is not allowed to replace the individual LED-modules of this light fitting.