Manual
LS101 / LSW101
Schulte-Schlagbaum AG
Page 22 of 39
LS(W)101_6-703-2 30R1 4_EN.DOCX
Information
LED display
All important actions and operating modes are indicated by the
LED display, the aim being to provide assistance in finding faults
and operating errors. An explanation of the individual signals is
provided in the table below.
LED display
Display
Action
Flashing
Programming mode
Every 1 second
Blocking time (one minute) is
active. An incorrect code was
entered five times
0.2 seconds
Key input
0.5 seconds
Error or Abort key (‘X’) was
pressed
LEDs flash twice
Handling error, the rotary knob
was not actuated within the
release time
Flashing
Rotary knob actuation expected
1 second
LS(W)101 was locked /
programming successful
2 seconds
LS(W)101 was unlocked
0.5 seconds
Code was accepted
3 seconds
Internal function fault / LS(W)101
must be replaced where
necessary
LEDs flash
together three
times
Warning: Battery should be
replaced soon
LEDs flash
alternatively five
times
Battery must be replaced
immediately, LS(W)101 can no
longer be locked
LEDs flash three
times
Reset performed