Manual
LS101 / LSW101
Schulte-Schlagbaum AG
Page 26 of 39
LS(W)101_6-703-2 30R1 4_EN.DOCX
LS101 installation notes
1 Housing
2
Nuts
(SW24) to fasten the LS101 on the door (for door thicknesses
1 mm to 18 mm)
Step nuts to fasten the LS101 on the door (for door thicknesses > 18 mm to 20 mm)
3
Washers to set the direction of rotation of the rotary knob for locking
4
Locking levers*
(depending on the cabinet type, a cranked or hooked
locking lever can be used.)
5
Fixing screws*
(SW10) for the locking lever
6 Sleeve
to fasten the LS101 on the door, door thicknesses >
10 mm to 20 mm
7 Sleeve
to fasten the LS101 on the door, door thicknesses from
1 mm to 10 mm
8
Screws*
(TX20) to fasten the LS101 on the door
9
Rotary knob
* Note:
The locking lever (4) must be held secured when tightening the fastening screw (5).
The fastening screws (5 and 8) may be tightened with a maximum torque of 3 Nm. Higher torques
can damage the coupling mechanism.
*