Manual
LS101 / LSW101
Schulte-Schlagbaum AG
Page 30 of 39
LS(W)101_6-703-2 30R1 4_EN.DOCX
LSW101 installation
Installation of outer housing
Installation of the outer housing requires two holes for the fastening screws and one hole for the
cable bushing.
Installation of the outer housing requires
three holes with a diameter of 7 mm.
Since the screw heads on the inside of the door
are covered by the inner housing, the holes for
installation of the outer housing must be drilled
at the height of the mounting holes of the inner
housing. The lateral position of the outer
housing must be in the range of 22-72 mm. (see
diagram)
The length of the M4 fastening screws must be
selected according to the thickness of the
existing door.
The following standard lengths are available:
Door thickness 10-15 mm
2 x M4x10
Door thickness 16-21 mm
2 x M4x16
Special lengths:
Door thickness 22-25 mm
2 x M4x20
Door thickness 26-30 mm
2 x M4x25
Note:
Incorrect screw lengths can cause damage of
the outer housing.