Manual
LS101 / LSW101
Schulte-Schlagbaum AG
Page 33 of 39
LS(W)101_6-703-2 30R1 4_EN.DOCX
Installation instructions for the LSW101
This section provides a brief summary for installation of the SAFE-O-TRONIC access LSW furniture
locking system, together with a few tips.
A drilling template is optionally available for positioning the fastening holes.
All furniture locks are supplied with factory settings (not programmed). Locking functions for
testing the lock and checking ease of operation of the bolt can be carried out with the Test
Code.
The first function test should be performed when the door is open. The sensing slide is not
active in the factory pre-set state. A locking operation can consequently be carried out with
the Test Code even when the door is open.
The bolt is motor-driven. To be able to ensure proper functioning, the bolt must move
smoothly when the door is closed. Should this not be the case, the door must be aligned.
The
door must be flush with the cabinet body. The door cannot automatically open in the ‘not
locked’ state, e.g. as a result of tension between the door and cabinet body.
The outer and inner housing are connected by means of a cable. This connector cable may
not be pinched during installation.
The battery connector may only be attached once the outer and inner housings have been
connected.