SAG
SAFE-O-TRONIC
Installation
Schulte-Schlagbaum AG
Page 10 of 12
SOT-Manual.DOC
6. Battery
The battery in the
SAFE-O-TRONIC
is designed for at least 40 actuations daily within a period of
3 years. The time when the battery needs to be replaced will depend however on the self-
discharging of the battery and by climatic effects, especially cold temperatures.
To summarize, the time to replace the battery depends on the following factors:
1. the number of actuations,
2. how long the battery has been installed, and
3. the ambient temperature in which the
SAFE-O-TRONIC
is operated.
6.1. Battery replacement
The battery compartment integrated into the lock body is only accessible when the cabinet is
opened, and can only be opened using a special screwdriver (Type:
ID ML.SSD-A)
.
•
After opening the battery compartment, disconnect the discharged battery pack at the connec-
tor and plug in the new battery pack.
•
Once the new battery pack has been installed, the
SAFE-O-TRONIC
is ready for immediate
use.
•
The discharged battery pack must be properly disposed of according to prevailing envi-
ronmental regulations!
NOTE:
Use only batteries recommended by the manufacturer (Type: ID ML.BP-A). The use
of non-approved batteries may cause malfunctions and result in damage to the
SAFE-O-TRONIC .
7. Service / Maintenance
The mechanical parts of the
SAFE-O-TRONIC
are maintenance-free. Under no circum-
stances use mineral oil based lubricants or greases.
Clean only using non-sticky, non-residue cleaners and disinfectants. Do not use harsh sol-
vents, acids or lye for cleaning.